Low amplitude of circadian rest-activity rhythm was associated with a 41% higher risk of incident atrial fibrillation (HR 1.41) compared to high amplitude in the general population.
Cohort (n=62,927)
Yes
Do accelerometer-derived circadian abnormalities and high genetic risk increase the incidence of atrial fibrillation in a general population without prior AF?
Accelerometer-measured circadian rhythm abnormalities, particularly when combined with high genetic risk, are significantly associated with an increased risk of incident atrial fibrillation in the general population.
Effect estimate: HR 1.41 (95% CI 1.25-1.58)
Evidence suggests potential links between circadian rhythm and atrial fibrillation (AF). However, whether circadian disruption can predict the onset of AF in the general population remains largely unknown. We aim to investigate the association of accelerometer-measured circadian rest-activity rhythm (CRAR, the most prominent circadian rhythm in humans) with the risk of AF, and examine joint associations and potential interactions of CRAR and genetic susceptibility with AF incidence. We include 62,927 white British participants of UK Biobank without AF at baseline. CRAR characteristics, including amplitude (strength), acrophase (timing of peak activity), pseudo-F (robustness), and mesor (height), are derived by applying an extended cosine model. Genetic risk is assessed with polygenic risk scores. The outcome is the incidence of AF. During a median follow-up of 6.16 years, 1920 participants developed AF. Low amplitude hazard ratio (HR): 1.41, 95% confidence interval (CI): 1.25-1.58, delayed acrophase (HR: 1.24, 95% CI: 1.10-1.39), and low mesor (HR: 1.36, 95% CI: 1.21-1.52), but not low pseudo-F, are significantly associated with a higher risk of AF. No significant interactions between CRAR characteristics and genetic risk are observed. Joint association analyses reveal that participants with unfavourable CRAR characteristics and high genetic risk yield the highest risk of incident AF. These associations are robust after controlling for multiple testing and in a series of sensitivity analyses. Accelerometer-measured CRAR abnormalities, characterized by decreased strength and height, and later timing of peak activity of circadian rhythm, are associated with a higher risk of AF in the general population.
Yang et al. (Sat,) conducted a cohort in Atrial fibrillation (n=62,927). Circadian rest-activity rhythm (CRAR) abnormalities (low amplitude) vs. Normal CRAR (high amplitude) was evaluated on Incidence of atrial fibrillation (HR 1.41, 95% CI 1.25-1.58). Low amplitude of circadian rest-activity rhythm was associated with a 41% higher risk of incident atrial fibrillation (HR 1.41) compared to high amplitude in the general population.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: