Abstract To compare the diagnostic value of ultrahigh-resolution CT-angiography (UHR-CTA) compared with high-pitch spiral CTA (HPS-CTA) using a first-generation, dual-source photon-counting CT (PCD-CT) scanner for preprocedural planning of transcatheter aortic valve replacement (TAVR). Clinically referred patients with severe aortic valve stenosis underwent both, retrospective ECG-gated cardiac UHR-CTA (collimation: 120 × 0.2 mm) and prospective ECG-triggered aortoiliac HPS-CTA (collimation: 144 × 0.4 mm, full spectral capabilities) for TAVR planning from August 2022 to March 2023. Radiation dose was extracted from the CT reports, and the effective dose was calculated. Two radiologists analyzed UHR-CTA and HPS-CTA datasets, assessing the image quality of the aortic annulus, with regard to the lumen visibility and margin delineation using a 4-point visual-grading scale (ranges: 4 = ”excellent” to 1 = ”poor”). Aortic annulus area (AAA) measurements were taken for valve prosthesis sizing, with retrospective UHR-CTA serving as reference standard. A total of 64 patients were included (mean age, 81 years ± 7 SD; 28 women) in this retrospective study. HPS-CTA showed a lower radiation dose, 4.1 mSv vs. 12.6 mSv (p < 0.001). UHR-CTA demonstrated higher image quality to HPS-CTA (median score, 4 IQR, 3–4 vs. 3 IQR, 2–3; p < 0.001). Quantitative assessments of AAA from both CTA datasets were strongly positively correlated (mean 477.4 ± 91.1 mm 2 on UHR-CTA and mean 476.5 ± 90.4 mm 2 on HPS-CTA, Pearson r 2 = 0.857, p < 0.001) with a mean error of 22.3 ± 24.6 mm 2 and resulted in identical valve prosthesis sizing in the majority of patients (91%). Patients with lower image quality on HPS-CTA (score value 1 or 2, n = 28) were more likely to receive different sizing recommendations (82%). Both UHR-CTA and HPS-CTA acquisitions using photon-counting CT technology provided reliable aortic annular assessments for TAVR planning. While UHR-CTA offers superior image quality, HPS-CTA is associated with lower radiation exposure. However, severely impaired image quality on HPS-CTA may impact on prosthesis sizing, suggesting that immediate post-scan image evaluations may require complementary UHR-CTA scanning.
Building similarity graph...
Analyzing shared references across papers
Loading...
Muhammad Taha Hagar
Theresa Kluemper
Manuel Hein
The International Journal of Cardiovascular Imaging
University of Freiburg
Ruhr University Bochum
University Medical Center Freiburg
Building similarity graph...
Analyzing shared references across papers
Loading...
Hagar et al. (Thu,) studied this question.
www.synapsesocial.com/papers/68e78f66b6db643587701038 — DOI: https://doi.org/10.1007/s10554-024-03050-w