Key points are not available for this paper at this time.
The char layer plays a critical role in the fire behaviour of engineered timber. Several chemical and physical processes can reduce char layer thickness and integrity. A series of experiments studied 12 cross-laminated timber (CLT) columns (130x790x125 mm WxHxD) exposed to combined thermal (20 kW/m2 or 50 kW/m2) and mechanical loading (39 kN, eccentric). Char loss from the surface lamella was observed and the impact of this on the thermal response of the timber studied. In all cases, unprotected CLT exhibited fall-off of charred pieces. Cracking, shrinkage and movement of char contributed significantly to the exposure of underlying timber sections to external heating. There was no direct correlation between char fall-off and the measured glue line temperature in this configuration. To enable comparison between CLT with and without char fall-off, a thin layer of glass fibre-reinforced polymer was added to the exposed surface of six samples which prevented all char fall-off. Retention of the char layer significantly decreased temperatures beneath the char layer, loss of section and burning duration compared to samples with char fall-off.
Building similarity graph...
Analyzing shared references across papers
Loading...
Laura Schmidt
Rory M. Hadden
Dilum Fernando
Fire Safety Journal
University of Edinburgh
The University of Queensland
Ghent University
Building similarity graph...
Analyzing shared references across papers
Loading...
Schmidt et al. (Tue,) studied this question.
www.synapsesocial.com/papers/68e6634ab6db6435875efe12 — DOI: https://doi.org/10.1016/j.firesaf.2024.104196