Key points are not available for this paper at this time.
Aims: This investigation aimed to examine the impact of autoclave sterilization on the cyclic fatigue of AF-F ONE, ProTaper Ultimate, and ProTaper Gold. Materials and Methods: Sixty #25 rotary files were categorized into groups as follows: AF-F ONE (Group A), ProTaper Ultimate (Group B), and ProTaper Gold (Group C). Additionally, within each group, there were subdivisions into sterilized and non-sterilized subgroups. Sterilized instruments underwent five cycles of sterilization by autoclave. Cyclic fatigue resistance was evaluated using a simulated canal featuring a single curvature (60° angle, 5-mm radius). Files were operated until fracture, and time and number of cycles to fracture (NCF) were recorded. Statistical analysis: One-way ANOVA, Post hoc Tukey test, and independent t-test. Results: ANOVA indicated a significant difference among non-sterilized groups (p 0.05).AF-F ONE significantly decreased after autoclave sterilization (p 0.05). Conclusion: Autoclave sterilization significantly affected the cyclic fatigue of AF-F ONE, whereas ProTaper Ultimate and ProTaper Gold demonstrated resilience. Keywords: Cyclic fatigue, ProTaper Ultimate, AF-F ONE, autoclave sterilization.
Najeeb et al. (Sun,) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: