ECG smart chest patches and PPG smartwatches both exhibited excellent performance in atrial fibrillation detection, with pooled sensitivities of 96.1% and 97.4%, respectively.
Meta-Analysis (n=12,802)
Yes
Do ECG smart chest patches and PPG smartwatches improve atrial fibrillation detection in adults?
Both ECG smart chest patches and PPG smartwatches exhibit excellent and comparable diagnostic accuracy for detecting atrial fibrillation, supporting their use in digital cardiac monitoring.
Absolute Event Rate: 96.1% vs 97.4%
INTRODUCTION: Atrial fibrillation (AF), the most common form of cardiac arrhythmia, is associated with significant morbidity, mortality, and financial burden. Traditional diagnostic methods, such as 12-lead electrocardiograms (ECG), have limitations in detecting intermittent AF episodes. Consequently, smart wearables have been introduced to enhance continuous AF monitoring. This systematic review and meta-analysis aimed to evaluate and compare the diagnostic accuracy of ECG smart chest patches and photoplethysmography (PPG)- based smartwatches in AF detection. METHODS: From august 16-20, 2024, a comprehensive search was conducted across PubMed/MEDLINE, DOAJ, AJOL, and the Cochrane Library. Original studies assessing the performance of ECG smart chest patches and PPG smartwatches in detecting AF were included. Studies were screened based on predefined inclusion and exclusion criteria, and the most relevant were finally included. For ECG smart chest patches and PPG smartwatches groups, random-effects model was used to pool these performance metrics. Statistical analyses were performed using Jamovi 2.3.28, with a significance threshold of p < 0.05. RESULTS: A total of 15 studies were included in the current systematic review and meta-analysis. ECG smart chest patches demonstrated a pooled sensitivity of 96.1% (95% CI: 91.3-100.8), (I² = 94.59%), and a pooled specificity of 97.5% (95% CI: 94.7-100.2), (I² = 79.1%). PPG smartwatches showed a pooled sensitivity of 97.4% (95% CI: 96.5-98.3), (I² = 3.16%), and a pooled specificity of 96.6% (95% CI: 94.9-98.3), (I² = 75.94%). Comparatively, both ECG smart chest patches and PPG smartwatches exhibited excellent performance in atrial fibrillation detection, with PPG smartwatches showing slightly higher sensitivity and ECG chest patches exhibiting marginally greater specificity. CONCLUSION: Both ECG smart chest patches and PPG smartwatches are highly effective for detecting atrial fibrillation. However, further advancements are needed to match their accuracy with that of standard diagnostic methods and achieve comprehensive digital cardiac monitoring.
Sibomana et al. (Tue,) conducted a meta-analysis in Atrial fibrillation (n=12,802). ECG smart chest patches vs. PPG smartwatches was evaluated on Pooled sensitivity for atrial fibrillation detection. ECG smart chest patches and PPG smartwatches both exhibited excellent performance in atrial fibrillation detection, with pooled sensitivities of 96.1% and 97.4%, respectively.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: