This study evaluates the feasibility of continuous indoor pollutant monitoring as an indirect method for assessing extended ventilation performance in residential buildings. This research addresses key limitations of conventional short-term tracer-gas methods, which cannot account for occupant lifestyle, environmental fluctuations, and extended ventilation variability. The study employs a diffusion-based framework to interpret pollutant-concentration equalization across the residential space over extended monitoring periods. We conducted field experiments in an apartment unit equipped with both ducted and non-ducted ventilation systems. Pollutants (PM2.5, CO2, HCHO, and aromatic VOCs (BTEX + styrene)) were uniformly emitted. PM2.5 and CO2 were continuously monitored at six spatially distributed points using calibrated sensors, while HCHO and aromatic VOCs were quantified by repeated active sampling and laboratory analysis. Under ducted ventilation, average pollutant reduction rates reached 86.8% for PM2.5, 58.3% for CO2, and 53.6% for HCHO. Simultaneously, spatial concentration variance decreased by up to 71% within 120 min, indicating strong diffusion-driven equalizations. These results support the feasibility of extended ventilation performance monitoring using continuous pollutant sensing, with implications for IAQ management, energy optimization, and future integration with data-driven predictive models.
Hwang et al. (Tue,) studied this question.