Biological fish possess the intrinsic ability to dynamically modulate body stiffness to adapt to varying fluid environments, thereby optimizing propulsive efficiency, swimming speed, and maneuverability. In contrast, this capability remains a significant challenge for most existing robotic fish, which typically rely on fixed-stiffness configurations. This article presents a comprehensive review of variable stiffness structures and their applications in biomimetic robotic fish. The associated technologies are systematically classified into four categories: smart material-driven, bio-inspired, fluid-driven, and hybrid-driven mechanisms. A comparative analysis of state-of-the-art prototypes is conducted, evaluating critical performance metrics including physical dimensions, maximum swimming speed, minimum turning radius, maximum turning rate, and Strouhal number. Furthermore, the specific advantages and technical limitations of each variable stiffness category are critically assessed. Finally, existing challenges in current research are identified, and prospective directions are proposed. The review demonstrates that variable stiffness technology offers significant potential to advance the hydrodynamic performance of robotic fish and facilitate their deployment in practical engineering applications.
Shao et al. (Wed,) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: