The QuantiPlaque deep learning model demonstrated strong correlation and agreement with expert annotation for per-patient total plaque volume (ICC 0.95) and calcified plaque volume (ICC 0.90).
Observational (n=115)
Does a deep learning model accurately quantify total and calcified coronary plaque volume on CCTA compared to expert manual annotation?
115 CCTA scans from patients with a mean age of 58 (range 51-64), 51% female, and mean coronary artery calcium score of 56 Agatston units.
Automated segmentation of total and calcified coronary plaque volume using a novel deep learning model (QuantiPlaque)
Expert manual annotation (reference standard)
Correlation and agreement between deep learning and expert segmentation for per-patient total plaque volume and calcified plaque volumesurrogate
A novel deep learning model provides accurate automated quantification of total and calcified coronary plaque volume on CCTA, showing strong agreement with expert manual annotation.
Effect estimate: ICC 0.95 (95% CI 0.92-0.96)
Abstract Background Coronary Computed Tomography Angiography (CCTA) is an established tool for assessing coronary artery disease. CCTA determined total coronary artery plaque volume predicts cardiovascular events, but manual quantification is impractical for routine use. Deep learning-based methods offer a promising solution for automated plaque volume assessment. Methods We developed and validated a novel software, QuantiPlaque , powered by deep learning models, for automated segmentation of total and calcified coronary plaque volume. Expert manual annotation served as the reference standard. Correlations between deep learning and expert segmentation were evaluated using intraclass correlation coefficient (ICC), Pearson’s r, and Spearman’s rho, and agreements were evaluated with Bland-Altman analyses. Results A total of 115 CCTA scans were included. Mean (range) age was 58 (51–64) and 51% were females. The mean coronary artery calcium score was 56 Agatston units, ranging from 0 to 601. The model demonstrated strong correlation and agreement with expert annotation for per-patient total plaque volume (ICC 0.95, mean difference − 8.35 mm 3 , 95% limit of agreement − 102 to 85 mm 3 , Spearman’s rho 0.87, Pearson’s r 0.95) and calcified plaque volume (ICC 0.90, mean difference − 0.28 mm 3 , 95% limits of agreement − 21.97 to 21.42 mm 3 , Spearman’s rho 0.93, Pearson’s r 0.90). Per-vessel analysis showed strong correlation in the left anterior descending artery and right coronary artery but was weaker in the left circumflex artery territory. Conclusion The evaluated deep learning model provides accurate quantification of total and calcified plaque burden, with strong correlation and agreement to expert annotation.
Building similarity graph...
Analyzing shared references across papers
Loading...
Johan Malmqvist
Linnaeus University
Tomas Jernberg
General Cardiology
Ramtin Vedad
Danderyds sjukhus
BMC Medical Imaging
Karolinska Institutet
KTH Royal Institute of Technology
Danderyds sjukhus
Building similarity graph...
Analyzing shared references across papers
Loading...
Malmqvist et al. (Thu,) conducted a observational in Coronary artery disease (n=115). QuantiPlaque deep learning model vs. Expert manual annotation was evaluated on Per-patient total plaque volume correlation (ICC 0.95, 95% CI 0.92-0.96). The QuantiPlaque deep learning model demonstrated strong correlation and agreement with expert annotation for per-patient total plaque volume (ICC 0.95) and calcified plaque volume (ICC 0.90).
synapsesocial.com/papers/6a080acea487c87a6a40cd48 — DOI: https://doi.org/10.1186/s12880-026-02379-z