Abstract Understanding the interaction of skin with surfaces is important in many applications such as medicine, bioelectronics and consumer products, depending on the grip, dexterity and feel of the objects. These phenomena are governed by frictional forces, which are intrinsically linked to real area of contact. The real contact area, in turn, is modulated by factors such as skin hydration and topographical roughness of the interacting surfaces. In this work, a new high-resolution Optical Coherence Tomography (OCT) tool due to its ability to penetrate and image the skin layers at high resolution, developed in-house, was used to analyse the real contact area and the stratum corneum (SC) thickness in finger-pad interfaces. Data were compared with a lower-resolution VivoSight® OCT device used in previous work. Forty-seven finger-pad sliding tests against smooth glass were performed with forces ranging from 0.5 – 3N. Post-test analyses of the OCT images captured revealed that the real measured contact area was 54% of the apparent contact area using the high-resolution OCT device in comparison to 63% measured with the VivoSight OCT. This underscores the rationale for employing a high-resolution OCT system, as it enables precise visualisation of the contact perimeter at the tribological interface, thereby facilitating a more accurate quantification of interfacial geometry and contact mechanics. The thickness of the SC was also seen to increase during sliding under the high-resolution OCT device. This resulted from the high skin deformation, which in turn influenced the contact area.
Maiti et al. (Thu,) studied this question.