This paper deals with the analysis of the process parameters such as pH, bath temperature, current density, plating time and voltage as influencing factors, on the weight and hardness of coating, based on Taguchi’s experimental design methods. This paper also compares the previous analysis to one based on Taguchi’s robust design idea to TOPSIS method of ranking. Attribute databases of MADM-TOPSIS are able to store, organise and manipulate both, the customer requirements and the product information for the performance of electroplating process system. The Taguchi method was adopted to determine the contribution of different factors using L27 orthogonal array for five electroplating parameter such as pH, temperature of bath, current density, plating time and voltage, with three levels for each factor. This study confirms the interest of usual DOEs as well as MADM technique, namely TOPSIS for experiment.
Kumar et al. (Sat,) studied this question.