November 16, 2009Anesthesia & Analgesia28 citations

Stroke Volume Variation During Acute Normovolemic Hemodilution

View Full Paper
GKGudrun KungysDRDavid D. RoseNFNeal Fleming

Key Result

Stroke volume variation derived from the FloTrac/Vigileo system increased significantly from 9.2% to 20.3% (P<0.001) after removal of 15% of estimated blood volume during hemodilution.

Study Design

Type

Observational (n=25)

Structured PICO

Does stroke volume variation derived from an arterial pressure-based monitor track changes in intravascular volume and correlate with 3D TEE LV volume during acute normovolemic hemodilution?

P
Population
25 surgical patients undergoing intraoperative acute normovolemic hemodilution
I
Intervention
Stroke volume variation (SVV) monitoring using an arterial pressure-based cardiac output monitor (FloTrac/Vigileo) during blood removal (up to 15% of estimated blood volume) and replacement (with 6% hetastarch)
C
Comparator
Baseline values and 3-dimensional transesophageal echocardiographic (TEE) left ventricular volume measurements
O
Outcome
Changes in SVV associated with blood removal and replacement, and correlation between SVV and 3D TEE LV volume measurementssurrogate

SVV derived from an arterial pressure-based monitor accurately tracks intravascular volume changes during acute normovolemic hemodilution and correlates with 3D TEE LV volume measurements.

Main Result

Absolute Event Rate: 20.3% vs 9.2%

p-value: p=<0.001

Abstract

BACKGROUND: The intravascular volume of surgical patients should be optimized to avoid complications associated with both overhydration and underresuscitation. In patients undergoing intraoperative acute normovolemic hemodilution, we investigated whether stroke volume variation (SVV) derived from an arterial pressure-based cardiac output (CO) monitor system (FloTrac/Vigileo™, Edwards Lifesciences, Irvine, CA) tracked the changes associated with blood removal and replacement. We further evaluated the correlations between SVV and 3-dimensional (3D) transesophageal echocardiographic (TEE) left ventricular (LV) volume measurements. METHODS: Twenty-five patients had procedures during which acute normovolemic hemodilution was a planned part of the intraoperative management. We defined 7 measurement timepoints: baseline, after the removal of 5%, 10%, and 15% of the estimated blood volume (EBV) and after replacement with an equal volume of 6% hetastarch to −10%, −5%, and baseline EBV. At each timepoint, heart rate and systolic, diastolic, and mean arterial blood pressure were obtained from standard monitors, CO and SVV measurements were obtained from the FloTrac/Vigileo monitor, and TEE images were recorded for subsequent off-line reconstruction and determination of LV end-systolic and end-diastolic volumes. For statistical evaluations, we used a mixed models analysis of variance and Dunnett’s test for post hoc comparisons with baseline values. Pearson’s correlation was used to examine the relationships between SVV and LV volume. RESULTS: Analysis of variance demonstrated no significant change in heart rate or mean arterial blood pressure over the duration of study. CO decreased from 4.9 ± 0.3 to 4.5 ± 0.3 L/min after removal of 15% of the EBV and then increased to a final value of 5.4 ± 0.3 L/min after replacement of 15% of the EBV. SVV increased from 9.2% ± 0.9% to 20.3% ± 2.0% (P < 0.001) after removal of 15% of the EBV and returned to a final value of 7.2% ± 0.9% after replacement of 15% of the EBV. The indexed LV end-diastolic volume decreased from 42.1 ± 8.3 to 36.9.3 ± 8.3 mL/m2 (P < 0.001) after removal of 15% of the EBV and then returned to a final volume of 45.9 ± 10.3 mL/m2 after replacement of 15% of the EBV. The measurements of SVV correlated inversely with the 3D TEE LV volume measurements. CONCLUSIONS: The SVV derived from the FloTrac/Vigileo system changes significantly as blood is removed and replaced during hemodilution. These changes correlate with 3D TEE measurements of LV volume. The utility of SVV in guiding optimization of intravascular volume merits further study.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Kungys et al. (2009) conducted an observational in Surgical patients undergoing intraoperative acute normovolemic hemodilution (n=25). Acute normovolemic hemodilution vs. Baseline was evaluated on Stroke volume variation (SVV) after removal of 15% of estimated blood volume (p=<0.001). Stroke volume variation derived from the FloTrac/Vigileo system increased significantly from 9.2% to 20.3% (P<0.001) after removal of 15% of estimated blood volume during hemodilution.