Does LV ejection fraction adequately reflect LV systolic function in patients with chronic mitral regurgitation before and after mitral valve surgery?
LV ejection fraction is an inadequate measure of true LV systolic function in chronic mitral regurgitation, as it appears normal pre-operatively due to left atrial unloading and decreases post-operatively despite actual improvements in myocardial performance.
Left ventricular (LV) ejection fraction may not adequately detect a reduction in LV systolic performance resulting from chronic mitral regurgitation (MR), due to ventricular unloading into the low-impedance left atrium. To determine whether LV ejection fraction sufficiently gauges myocardial function in MR, nine patients were studied using micromanometer-measured LV pressures and biplane cineventriculography before and 1 year after mitral valve surgery. Six control patients were also studied. LV ejection fraction was normal in MR patients, despite an increase in LV end-systolic volume index. LV end-systolic pressure-volume and stress-volume ratios in MR patients were lower than in controls (P < 0.05 and P < 0.01), suggesting that LV systolic performance fell. One year after mitral valve surgery, LV ejection fraction decreased (P < 0.05) even though LV end-systolic volume index (P < 0.05), pressure-volume (P < 0.05), and stress-volume ratios (P < 0.01) all improved. Thus, LV ejection fraction inadequately reflected LV systolic function in MR patients before and after mitral valve surgery.
Timmis et al. (Wed,) studied this question.