PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
July 29, 2022Journal of Nuclear Medicine9 citationsOpen Access

68Ga-DOTATATE Prepared from Cyclotron-Produced68Ga: An Integrated Solution from Cyclotron Vault to Safety Assessment and Diagnostic Efficacy in Neuroendocrine Cancer Patients

STSébastien TremblayJBJean-François BeaudoinOBOphélie Bélissant Benesty

Key Points

Key points are not available for this paper at this time.

Abstract

Cyclotron production of gallium-68 (68Ga) is a promising approach to supply 68Ga radiopharmaceuticals. To validate this capability, an integrated solution for a robust synthesis of 68Ga-DOTATATE prepared from cyclotron produced 68Ga (further on referred to as cyclotron produced 68Ga-DOTATATE) was achieved. A retrospective comparison analysis was performed in patients who underwent PET/CT imaging after injection of DOTATATE labeled with 68Ga produced by cyclotron or eluted from a generator to demonstrate the clinical safety and diagnostic efficacy of the radiopharmaceutical for a routine standard-of-care diagnostic tool in clinic. Methods: An enriched zinc-68 pressed target was irradiated by cyclotron with a proton beam set at 12.7 MeV for 100 min. The fully automated process utilizes an in-vault dissolution system where a liquid distribution system transfers the dissolved target to a dedicated hotcell for the purification of 68GaCl3 and radiolabeling of DOTATATE using a cassette-based automated module. Quality control tests were performed on the resulting tracer solution. The internal radiation dose for 68Ga-DOTATATE was calculated based on extrapolation from rat biodistribution experiments. A retrospective comparison analysis was performed in patients who underwent PET/CT imaging after injection of DOTATATE labeled with 68Ga produced by cyclotron or eluted from a generator. Results: The synthesis of 68Ga-DOTATATE (20.7 ± 1.3 GBq) with high apparent molar activity (518 ± 32 GBq/µmole at end of synthesis (EOS)) was completed in 65 min and the radiopharmaceutical met the requirements specified in the European Pharmacopeia monograph on Gallium (68Ga) chloride (accelerator produced) solution for radiolabeling. 68Ga-DOTATATE was stable for at least 5 h after formulation. The dosimetry calculated with OLINDA for 68Ga-DOTATATE from cyclotron produced 68Ga and generator eluted 68Ga was roughly equivalent. The SUVmean or SUVmax of tumoral lesions with cyclotron produced 68Ga-DOTATATE was equivalent to that with generator-eluted 68Ga. Among physiological uptakes, a significant difference was found in kidneys, spleen and stomach wall, with lower values in cyclotron produced 68Ga-DOTATATE in all cases. Conclusion: Integrated cyclotron production achieves reliable high yields of clinical-grade 68Ga-DOTATATE. The clinical safety, and imaging efficacy of cyclotron produced 68Ga-DOTATATE in humans provide supporting evidence for its use in routine clinical practice.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Tremblay et al. (2022) studied this question.

synapsesocial.com/papers/6a11c062485b54c5f7178f23https://doi.org/10.2967/jnumed.121.263768
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Automated radiosynthesis of 68Ga for large-scale routine production using 68Zn pressed target2019 · 34 citations
  2. 2Multi-curie production of gallium-68 on a biomedical cyclotron and automated radiolabelling of PSMA-11 and DOTATATE2021 · 62 citations
  3. 3Evaluated cross section and thick target yield data bases of Zn+p processes for practical applications1998 · 95 citations
  4. 4International Atomic Energy Agency2022 · 3,912 citations
  5. 5Somatostatin receptor sst1–sst5 expression in normal and neoplastic human tissues using receptor autoradiography with subtype-selective ligands2001 · 657 citations