Post-mortem histological analysis of the mitral isthmus (length 35+/-7 mm) revealed a ramus circumflexus <5 mm from the endocardium in 60% of superior sections, potentially complicating ablation.
Observational (n=16)
Normal left atria (n=16)
Histological analysis of the mitral isthmus
Anatomical characteristics of the mitral isthmus area to determine optimal lesion line location
AIMS: A linear lesion between the left inferior pulmonary vein orifice and mitral annulus, the so-called mitral isthmus, may improve the success of catheter ablation for atrial fibrillation. Gaps in the lesion line, however, may facilitate left atrial flutter. The aim of the study was to determine the optimal location of the lesion line by serial sectioning of the isthmus area. METHODS AND RESULTS: In a post-mortem study of 16 patients with normal left atria, serial sections of the isthmus area from 10 mm superior to and 30 mm inferior to the isthmus were studied by light microscopy. The length of the isthmus was 35+/-7 mm. On average, the muscle sleeve around the coronary sinus ended 10 mm inferior to the isthmus. The prevalence of a ramus circumflexus <5 mm from the endocardial surface, decreased from 60% in the most superior section to 0% in the most inferior section. Atrial arteries were frequently present in all sections. CONCLUSIONS: The thickness of atrial myocardium, the ramus circumflexus sometimes very close to the endocardium, a myocardial sleeve around the coronary sinus, and local cooling by atrial arteries and veins may complicate the creation of conduction block in the mitral isthmus.
Building similarity graph...
Analyzing shared references across papers
Loading...
Wittkampf et al. (Thu,) conducted a observational in Normal left atria (n=16). Histological analysis of the mitral isthmus was evaluated on Anatomical characteristics of the mitral isthmus area to determine optimal lesion line location. Post-mortem histological analysis of the mitral isthmus (length 35+/-7 mm) revealed a ramus circumflexus <5 mm from the endocardium in 60% of superior sections, potentially complicating ablation.
synapsesocial.com/papers/6a11de340aad52b339b4cdfd — DOI: https://doi.org/10.1093/eurheartj/ehi095
Fred H.M. Wittkampf
Electrophysiology
Matthijs F. van Oosterhout
St. Antonius Ziekenhuis
Peter Loh
Electrophysiology
European Heart Journal
Utrecht University
University Medical Center
Building similarity graph...
Analyzing shared references across papers
Loading...
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: