PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 10, 2021European Journal of Cardio-Thoracic Surgery20 citationsOpen Access

Transcatheter aortic valve replacement for structural degeneration of previously implanted transcatheter valves (TAVR-in-TAVR): a systematic review

View Full Paper
MGMichele GalloLFLuca Nai FovinoDBDavid Blitzer

Key Result

TAVR-in-TAVR for degenerated transcatheter valves achieved an 86.8% procedural success rate and 1.25% hospital mortality, offering a valid alternative to standard surgery in high-risk patients.

Study Design

Type

Systematic Review (n=160)

Multicenter

Yes

Structured PICO

Is TAVR-in-TAVR a safe and effective procedure for patients with structural degeneration of previously implanted transcatheter valves?

P
Population
160 patients treated with TAVR-in-TAVR procedures for transcatheter valve failure (mean age 74.8, 52.8% male) pooled from 13 studies.
I
Intervention
TAVR-in-TAVR (redo-TAVR procedure for degenerated transcatheter valves)
O
Outcome
Procedural success, mortality, complications, and follow-up outcomessafety

TAVR-in-TAVR represents a feasible and safe alternative to standard surgery for treating degenerated transcatheter valves in high-risk patients, demonstrating high procedural success and low hospital mortality.

Limitations

  • Further studies are required to assess durability and haemodynamic performances of the second TAVR valve

Abstract

OBJECTIVES: Transcatheter aortic valve replacement (TAVR) represents a valid treatment for patients with aortic valve stenosis and high or intermediate surgical risk. However, biological transcatheter valves can also experience a structural degeneration after years, and a redo-TAVR procedure (TAVR-in-TAVR) can be a valid option. We revised the current available literature for indications, procedural and technical details and outcome on TAVR-in-TAVR procedures for degenerated TAVR valves. METHODS: A systematic search was conducted in the public medical database for scientific articles on TAVR-in-TAVR procedures for degenerated transcatheter valves. Data on demographics, indications, first and second transcatheter valve type and size, mortality, complications and follow-up were extracted and analysed. RESULTS: A total of 13 studies (1 multicentre, 3 case series, 9 case reports) were included in this review, with a total amount of 160 patients treated with TAVR-in-TAVR procedures for transcatheter valve failure. The mean age was 74.8 ± 7.8 with 84 males (52.8%). The mean elapsed time from the first TAVR procedure was 58.1 ± 23.4 months. Main indication for TAVR-in-TAVR was pure stenosis (38.4%, with mean gradient of 44.5 ± 18.5 mmHg), regurgitation (31.4%), mixed stenosis and regurgitation (29.5%) and leaflet thrombosis (8.8%). Procedural success rate was 86.8%, with second TAVR valve malposition occurred in 4 cases (2.5%). The hospital mortality rate was 1.25% (2/160). Post-procedural echocardiographic control showed moderate regurgitation in 5.6% of patients (9/160) and residual transvalvular mean gradient ≥20 mmHg in 5% of cases. Postoperative complications included major vascular complications (8.7%), new pacemaker implantation (8.7%), acute kidney failure (3.7%), stroke (0.6%) and coronary obstruction (0.6%). The mean follow-up time was 6 ± 5.6 months with 1 non-cardiovascular death reported. CONCLUSIONS: TAVR-in-TAVR represents a valid alternative to standard surgery for the treatment of degenerated transcatheter valves in high-risk patients. Despite these promising results, further studies are required to assess durability and haemodynamic performances of the second TAVR valve.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Gallo et al. (2021) conducted a systematic review in Structural degeneration of previously implanted transcatheter valves (n=160). TAVR-in-TAVR was evaluated on Procedural success rate. TAVR-in-TAVR for degenerated transcatheter valves achieved an 86.8% procedural success rate and 1.25% hospital mortality, offering a valid alternative to standard surgery in high-risk patients.

synapsesocial.com/papers/6a1768ef8008e5848e6e9c5ahttps://doi.org/10.1093/ejcts/ezab443
Ask AI
Helpful
Bookmark
Share
View Full Paper