August 28, 2014Journal of the American College of Radiology243 citationsOpen Access

Performance of ACR Lung-RADS in a Clinical CT Lung Screening Program

View Full Paper
BMBrady J. McKeeSRShawn M. RegisAMAndrea B. McKee

Key Points

Key points are not available for this paper at this time.

Abstract

PURPOSE: The aim of this study was to assess the effect of applying ACR Lung-RADS in a clinical CT lung screening program on the frequency of positive and false-negative findings. METHODS: Consecutive, clinical CT lung screening examinations performed from January 2012 through May 2014 were retroactively reclassified using the new ACR Lung-RADS structured reporting system. All examinations had initially been interpreted by radiologists credentialed in structured CT lung screening reporting following the National Comprehensive Cancer Network's Clinical Practice Guidelines in Oncology: Lung Cancer Screening (version 1.2012), which incorporated positive thresholds modeled after those in the National Lung Screening Trial. The positive rate, number of false-negative findings, and positive predictive value were recalculated using the ACR Lung-RADS-specific positive solid/part-solid nodule diameter threshold of 6 mm and nonsolid (ground-glass) threshold of 2 cm. False negatives were defined as cases reclassified as benign under ACR Lung-RADS that were diagnosed with malignancies within 12 months of the baseline examination. RESULTS: A total of 2,180 high-risk patients underwent baseline CT lung screening during the study interval; no clinical follow-up was available in 577 patients (26%). ACR Lung-RADS reduced the overall positive rate from 27.6% to 10.6%. No false negatives were present in the 152 patients with >12-month follow-up reclassified as benign. Applying ACR Lung-RADS increased the positive predictive value for diagnosed malignancy in 1,603 patients with follow-up from 6.9% to 17.3%. CONCLUSIONS: The application of ACR Lung-RADS increased the positive predictive value in our CT lung screening cohort by a factor of 2.5, to 17.3%, without increasing the number of examinations with false-negative results.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

McKee et al. (2014) studied this question.

synapsesocial.com/papers/6a21f2593b8e99975a4e987ehttps://doi.org/10.1016/j.jacr.2014.08.004
Ask AI
Helpful
Bookmark
Share
View Full Paper