Key points are not available for this paper at this time.
) saturation magnetization. The volume fraction of iron NPs varies from 0.5 to 15% in the ferrofluid carrier which significantly increases the magnetization and simultaneously produces important changes of flow properties in magnetic field of the resulting composite fluid, from Newtonian to strongly non-Newtonian behavior. The evaluation of the magnetic and magnetorheological behavior includes the dependence of magnetization, effective viscosity, magnetoviscous effect and dynamic yield stress on the volume fraction of Fe nanoparticles dispersed in the ferrofluid carrier. The seal gap filled with interconnected Fe nanospheres consists in randomly distributed microregions with a high intensity and high gradient magnetic field that captures the ferrofluid and provides a new sealing mechanism. Already a small amount of interconnected Fe nanospheres additive (2.5-5.0% volume fraction) produces four times increase of the rotating seal burst pressure, a much higher increase than what can be obtained from using a conventional magnetic fluid with the same magnetization. The nano-composite sealing magnetic fluid proved to be a cost-effective solution to significantly increase the performance of multi-stage rotating MF seals.
Susan-Resiga et al. (Mon,) studied this question.