July 1, 1977The Journal of Physiology42 citationsOpen Access

Measurement of transmembrane potential and current in cardiac muscle: a new voltage clamp method.

View Full Paper
YGYale E. GoldmanHeart Failure / CardiomyopathyMMMartin MoradElectrophysiology

Key Points

  • To develop a new voltage clamp technique that accurately measures transmembrane potential and current in cardiac muscle.
  • Developed a sucrose gap voltage clamp with a guard gap to minimize leakage currents.
  • Utilized a 'pre-pulse' command potential to accelerate membrane capacitance charge.
  • Employed 'chopped current pulse clamp' to compensate for extracellular resistance during voltage steps.
  • Voltage and current traces stabilize within 2-4 msec after hyperpolarizing voltage clamp steps.
  • Conductance is higher at rest compared to the plateau of the action potential.
  • The instantaneous current-voltage relationship of the membrane is linear during the plateau phase.

Abstract

A single sucrose gap voltage clamp technique was developed to correct for artifacts of 'leakage' corrent and extracellular resistance making possible improved measurement of membrane current and membrane potential in cardiac muscle. 2. A fourth compartment termed 'guard gap' was added to the sucrose gap. The guard gap is maintained at the same potential as the Reinger pool, so that no extracellular leakage current can flow into the Ringer pool. Comparison of experimental results with the predictions of an idealized cable model indicates that the guard gap is effective in trapping leakage current. 3. The slow charging of membrane capacitance due to extracellular series resistance was accelerated by applying a 'pre-pulse' of the command potential past the final voltage clamp value. 4. A second technique, termed 'chopped current pulse clamp', was used to compensate for the extracellular resistance throughout the voltage clamp step. The applied current was turned on and off at a frequency of 0-5-2 kHz. The membrane potential sampled during the zero current phase was fed back through the clamp loop. 5. With either of these compensation techniques, the voltage and current traces settle to effectively constant values within 2-4 msec after initiation of a hyperpolarizing voltage clamp step from rest. 6. The membrane conductance measured by the prepulse and chopped current-pulse technique are equal and confirm a higher conductance at rest than during the plateau of the action potential. 7. The 'instantaneous' current-voltage relation of the membrane is linear during the plateau of the frog ventricular action potential.