PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 1, 1993AJP Heart and Circulatory Physiology63 citations

Pressure-independent baroreflex resetting produced by chronic infusion of angiotensin II in rabbits

View Full Paper
VBVirginia L. BrooksKEKathleen EllRWRalph Wright

Key Points

  • This research investigates whether chronic angiotensin II infusion resets baroreflex control of heart rate to a higher pressure level independent of hypertension.
  • Chronic intravenous infusion of ANG II (20 ng.kg-1 x min-1) for two weeks in rabbits.
  • Assessment of baroreflex by infusing nitroprusside to lower and phenylephrine to raise arterial pressure.
  • Monitoring plasma ANG II levels, arterial pressure, and heart rate over various time points during the infusion.
  • Plasma ANG II levels increased significantly from 9 +/- 1 to 146 +/- 24 pg/ml (P < 0.05).
  • Arterial pressure rose from 62 +/- 2 to 95 +/- 2 mmHg (P < 0.05).
  • The baroreflex control was elevated at a higher pressure level and reverted to control once ANG II was withdrawn.

Abstract

The purpose of this study was to test the hypothesis that chronic infusion of angiotensin II (ANG II) in rabbits shifts or resets baroreflex control of heart rate to a higher pressure level via a mechanism that is independent of the hypertension that is produced. The baroreflex relationship between arterial pressure and heart rate was assessed by first infusing progressively increasing doses of nitroprusside (3, 6, 12, 24, and 48 micrograms.kg-1 x min-1) to lower pressure and then increasing doses of phenylephrine (0.5, 1, 2, 4, and 8 micrograms.kg-1 x min-1) to raise pressure. Two weeks of intravenous ANG II infusion (20 ng.kg-1 x min-1) increased plasma ANG II levels from 9 +/- 1 to 146 +/- 24 pg/ml (P < 0.05), increased arterial pressure from 62 +/- 2 to 95 +/- 2 mmHg (P < 0.05), and transiently increased heart rate. The baroreflex was shifted to a higher pressure level after 30 min and 1, 3, 7, 9, and 14 days of ANG II infusion. Thirty minutes after the ANG II infusion on days 1, 7, and 14 was stopped, arterial pressure decreased, and the baroreflex shifted back to control, indicating that ANG II was required for the resetting that was produced. However, when the ANG II infusion was continued and arterial pressure was instead reduced for 30 min by infusing nitroprusside on days 3 and 9, the baroreflex relationship between arterial pressure and heart rate remained positioned at a higher pressure level.(ABSTRACT TRUNCATED AT 250 WORDS)

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Brooks et al. (1993) studied this question.

synapsesocial.com/papers/6a740685b7b02007e5a8c944https://doi.org/10.1152/ajpheart.1993.265.4.h1275
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Chronic Infusion of Angiotensin II Resets Baroreflex Control of Heart Rate by an Arterial Pressure–Independent Mechanism1995 · 44 citations
  2. 2Analysis of the Action of Angiotensin II on the Baroreflex Control of Heart Rate in Conscious Rabbits*1990 · 47 citations
  3. 3Angiotensin II-Dependent Hypertension and the Arterial Baroreflex1995 · 25 citations
  4. 4Angiotensin II modulates arterial baroreflex function via a central alpha 1-adrenoceptor mechanism in rabbits1995 · 18 citations
  5. 5Baroreflex Control of Heart Rate and Cardiac Hypertrophy in Angiotensin II–Induced Hypertension in Rabbits1997 · 27 citations