August 13, 2026Circulation305 citationsOpen Access

Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation

View Full Paper
MUMarina UreñaJWJohn G. WebbCTCorrado Tamburino

Key Result

Permanent pacemaker implantation within 30 days after TAVI was not associated with all-cause mortality (HR 0.98; 95% CI 0.74-1.30; P=0.871) after a mean follow-up of 22 months.

Key Points

  • This study aims to evaluate the effects of permanent pacemaker implantation after transcatheter aortic valve implantation on long-term outcomes.
  • Included 1556 patients without prior PPI undergoing transcatheter aortic valve implantation.
  • 239 patients (15.4%) required PPI within 30 days post-procedure.
  • Mean follow-up duration of 22 months.
  • No association between 30-day PPI and all-cause mortality (HR 0.98; 95% CI 0.74-1.30; P=0.871).
  • Lower rate of unexpected death in patients with PPI (HR 0.31; 95% CI 0.11-0.85; P=0.023).
  • New PPI predicted a decrease in left ventricular ejection fraction at 6-12 months (P=0.017).

Study Design

Type

Cohort (n=1,556)

Structured PICO

Does permanent pacemaker implantation within 30 days after transcatheter aortic valve implantation affect late mortality and heart failure outcomes in patients undergoing TAVI?

P
Population
1,556 consecutive patients without prior permanent pacemaker implantation undergoing transcatheter aortic valve implantation, followed for a mean of 22 months.
E
Exposure
Permanent pacemaker implantation (PPI) within the first 30 days after transcatheter aortic valve implantation
C
Comparator
No permanent pacemaker implantation within 30 days after transcatheter aortic valve implantation
O
Outcome
All-cause mortality, cardiovascular mortality, and composite of all-cause mortality or rehospitalization for heart failure at mean follow-up of 22±17 monthshard clinical

Permanent pacemaker implantation after TAVI does not increase long-term mortality or heart failure hospitalization, and may protect against sudden death, despite a negative impact on left ventricular ejection fraction.

Main Result

Hazard Ratio: 0.98 (95% CI 0.74–1.3)

p-value: p=0.871

Abstract

BACKGROUND: Very few data exist on the clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation. The objective of this study was to assess the impact of PPI after transcatheter aortic valve implantation on late outcomes in a large cohort of patients. METHODS AND RESULTS: A total of 1556 consecutive patients without prior PPI undergoing transcatheter aortic valve implantation were included. Of them, 239 patients (15.4%) required a PPI within the first 30 days after transcatheter aortic valve implantation. At a mean follow-up of 22±17 months, no association was observed between the need for 30-day PPI and all-cause mortality (hazard ratio, 0.98; 95% confidence interval, 0.74-1.30; P=0.871), cardiovascular mortality (hazard ratio, 0.81; 95% confidence interval, 0.56-1.17; P=0.270), and all-cause mortality or rehospitalization for heart failure (hazard ratio, 1.00; 95% confidence interval, 0.77-1.30; P=0.980). A lower rate of unexpected (sudden or unknown) death was observed in patients with PPI (hazard ratio, 0.31; 95% confidence interval, 0.11-0.85; P=0.023). Patients with new PPI showed a poorer evolution of left ventricular ejection fraction over time (P=0.017), and new PPI was an independent predictor of left ventricular ejection fraction decrease at the 6- to 12-month follow-up (estimated coefficient, -2.26; 95% confidence interval, -4.07 to -0.44; P=0.013; R(2)=0.121). CONCLUSIONS: The need for PPI was a frequent complication of transcatheter aortic valve implantation, but it was not associated with any increase in overall or cardiovascular death or rehospitalization for heart failure after a mean follow-up of ≈2 years. Indeed, 30-day PPI was a protective factor for the occurrence of unexpected (sudden or unknown) death. However, new PPI did have a negative effect on left ventricular function over time.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Ureña et al. (2013) conducted a cohort in Transcatheter aortic valve implantation (n=1,556). Permanent pacemaker implantation (PPI) within 30 days vs. No 30-day PPI was evaluated on All-cause mortality (HR 0.98, 95% CI 0.74-1.30, p=0.871). Permanent pacemaker implantation within 30 days after TAVI was not associated with all-cause mortality (HR 0.98; 95% CI 0.74-1.30; P=0.871) after a mean follow-up of 22 months.

synapsesocial.com/papers/6a7d37af595588f8c723d09ahttps://doi.org/10.1161/circulationaha.113.005479