March 28, 2014European Heart Journal206 citationsOpen Access

Treatment of aortic stenosis with a self-expanding transcatheter valve: the International Multi-centre ADVANCE Study

ALAxel LinkePWPeter WenaweserUGUlrich Gerckens

Structured PICO

P
Population
1015 patients with severe aortic stenosis at a higher surgical risk, mean age 81 ± 6 years, international multi-centre.
I
Intervention
Self-expanding transcatheter aortic valve system (CoreValve System) implantation.
O
Outcome
Composite of major adverse cardiovascular and cerebrovascular events (MACCE; all-cause mortality, myocardial infarction, stroke, or reintervention) and mortality at 30 days and 1 year, independently adjudicated based on Valve Academic Research Consortium definitions.composite

The ADVANCE study demonstrates that a self-expanding transcatheter aortic valve system is safe and effective, with low mortality and stroke rates at 1 year in high-risk real-world patients with severe aortic stenosis.

Abstract

AIM: Transcatheter aortic valve implantation has become an alternative to surgery in higher risk patients with symptomatic aortic stenosis. The aim of the ADVANCE study was to evaluate outcomes following implantation of a self-expanding transcatheter aortic valve system in a fully monitored, multi-centre 'real-world' patient population in highly experienced centres. METHODS AND RESULTS: Patients with severe aortic stenosis at a higher surgical risk in whom implantation of the CoreValve System was decided by the Heart Team were included. Endpoints were a composite of major adverse cardiovascular and cerebrovascular events (MACCE; all-cause mortality, myocardial infarction, stroke, or reintervention) and mortality at 30 days and 1 year. Endpoint-related events were independently adjudicated based on Valve Academic Research Consortium definitions. A total of 1015 patients mean logistic EuroSCORE 19.4 ± 12.3% [median (Q1,Q3), 16.0% (10.3, 25.3%), age 81 ± 6 years] were enrolled. Implantation of the CoreValve System led to a significant improvement in haemodynamics and an increase in the effective aortic valve orifice area. At 30 days, the MACCE rate was 8.0% (95% CI: 6.3-9.7%), all-cause mortality was 4.5% (3.2-5.8%), cardiovascular mortality was 3.4% (2.3-4.6%), and the rate of stroke was 3.0% (2.0-4.1%). The life-threatening or disabling bleeding rate was 4.0% (2.8-6.3%). The 12-month rates of MACCE, all-cause mortality, cardiovascular mortality, and stroke were 21.2% (18.4-24.1%), 17.9% (15.2-20.5%), 11.7% (9.4-14.1%), and 4.5% (2.9-6.1%), respectively. The 12-month rates of all-cause mortality were 11.1, 16.5, and 23.6% among patients with a logistic EuroSCORE ≤10%, EuroSCORE 10-20%, and EuroSCORE >20% (P< 0.05), respectively. CONCLUSION: The ADVANCE study demonstrates the safety and effectiveness of the CoreValve System with low mortality and stroke rates in higher risk real-world patients with severe aortic stenosis.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Linke et al. (2014) studied this question.

synapsesocial.com/papers/6a854988f14ace264a43d8c6https://doi.org/10.1093/eurheartj/ehu162
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Final 5-year clinical and echocardiographic results for treatment of severe aortic stenosis with a self-expanding bioprosthesis from the ADVANCE Study2017 · 72 citations
  2. 2Transcatheter Aortic Valve Replacement Using a Self-Expanding Bioprosthesis in Patients With Severe Aortic Stenosis at Extreme Risk for Surgery2014 · 1,046 citations
  3. 3Midterm Outcomes With a Self-Expandable Transcatheter Heart Valve in Japanese Patients With Symptomatic Severe Aortic Stenosis2017 · 7 citations
  4. 4Transcatheter aortic valve implantation without balloon predilation: A single‐center pilot experience2013 · 24 citations
  5. 5Progress and Current Status of Percutaneous Aortic Valve Replacement: Results of Three Device Generations of the CoreValve Revalving System2008 · 353 citations