August 1, 2018Diabetes Technology & Therapeutics62 citationsOpen Access

Measurement Performance of Two Continuous Tissue Glucose Monitoring Systems Intended for Replacement of Blood Glucose MonitoringParts of the data have previously been presented at the 77th Scientific Sessions of the American Diabetes Association in San Diego, CA; June 9–13, 2017 and at the 17th Annual Diabetes Technology Meeting in Bethesda, MD, November 2–4, 2017.Trial number: DRKS00011920; registered at the Deutsches Register Klinischer Studien (German clinical trials register), an approved Primary Register in the WHO International Clinical Trials Registry Platform.

View Full Paper
GFGuido FreckmannMLManuela LinkSPStefan Pleus

Key Points

Key points are not available for this paper at this time.

Abstract

BACKGROUND: G5 DG5 and FreeStyle Libre FL) are intended to replace blood glucose monitoring (BGM) and, according to manufacturer labeling, are distributed as such in some jurisdictions, including the United States and the European Union. METHODS: The measurement performance of these two systems in comparison with a BGM system was analyzed in a 14-day study with 20 participants comprising study site visits, which included phases of induced rapid glucose changes, and home use phases. Performance analysis was mainly based on deviations between CGM readings and BGM results. Sensor-to-sensor precision was also analyzed. RESULTS: Approximately 25% of DG5 and FL results showed differences from BGM results exceeding 15 mg/dL or 15% (at glucose concentration below or above 100 mg/dL, respectively) at times of therapeutic decisions, and ∼5% of differences exceeded 30 mg/dL or 30%. Performance was different depending on the setting (study site visits, home use phases, and phases of induced rapid glucose changes). In consensus error grid (CEG) analysis, both systems showed >99.5% of results within the clinically acceptable zones A and B. CONCLUSIONS: In this study, both systems showed deviations from blood glucose (BG) measurements, the current standard approach in diabetes therapy. Although a large percentage of results was found in CEG zones A and B, for approximately one in four therapeutic decisions, CGM and BG readings differed by at least 15 mg/dL or 15%. Such deviations should be taken into account when using CGM systems.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Freckmann et al. (2018) studied this question.

synapsesocial.com/papers/6a90a608be9662ac6285f317https://doi.org/10.1089/dia.2018.0105
Ask AI
Helpful
Bookmark
Share
View Full Paper