PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
August 17, 20250 citations

Validation of Compressor Surge Rundown Trajectories: Comparative Analysis of Transient Model Predictions and Test Rig Measurements

View Full Paper
OPOla Ilseth PronkASAlberto SerenaLBLars E. Bakken

Key Points

  • Modeling accurately predicts surge behaviour during shutdown events, enhancing system reliability.
  • Significant improvement in predictions noted, with a focus on time to surge and head rise sensitivity.
  • Dynamic analysis employs a revised surge model, tuning it with performance data for better outcomes.
  • Findings support the need for advanced transient models in turbomachinery applications, especially during critical operations.

Abstract

Abstract Dynamic simulation tools are crucial in the process industry for analysing transient operating scenarios. Accurate models are vital for developing digital twin and adaptive monitoring technologies for turbomachinery applications, particularly compressor systems. Such tools have traditionally been confined to the normal operating area, while specialised models have been required for instability analysis. Recent advances integrate surge models with general-purpose modelling tools, thereby extending their application to severe off-design operation in the surge area. This study documents the transient behaviour of an industrial-sized centrifugal compressor test rig during emergency shutdown. The test cases encompass driver trips and protection system responses, with a focus on the system stability and surge behaviour. The dynamic model, tuned with performance data and incorporating a revised surge model, demonstrates significant improvements over conventional models. Representative surge behaviour is obtained by shifting negatively sloped model curves with a head offset and time lag to match the positive-slope and second-quadrant compressor performance characteristics. The results highlight the accuracy and reproducibility attainable when using well-developed dynamic models and emphasise the importance of accounting for surge behaviour when simulating shutdown. System stability is quantified using the time to surge metric, and its sensitivity to head rise to surge and plenum volume variations is documented. The model’s ability to predict shifts in time to surge is validated.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Pronk et al. (2025) studied this question.

synapsesocial.com/papers/68a36f7d0a429f7973331e2ehttps://doi.org/10.1115/gt2025-151663
Ask AI
Helpful
Bookmark
Share
View Full Paper