August 19, 2025Energies0 citationsOpen Access

A Graph Deep Reinforcement Learning-Based Fault Restoration Method for Active Distribution Networks

View Full Paper
YDYangqing DanHZHui ZhongCWChenxuan Wang

Key Points

  • The proposed method achieves fault recovery in active distribution networks rapidly, revitalizing service in milliseconds.
  • It incorporates a graph attention network (GAT) with a soft actor–critic (SAC) algorithm, enhancing the agent’s perception of network statuses.
  • The study validates the method on IEEE 33-bus and 148-bus cases, showcasing performance improvements over baseline methods.
  • An innovative invalid action masking mechanism prevents illegal control actions during recovery procedures.

Abstract

The topology of distribution networks changes frequently, and the uncertainty of load level and distributed generator (DG) output makes the operation scenarios more complex and variable. Based on this, a fault recovery method for active distribution networks based on graph-based deep reinforcement learning is proposed. Firstly, considering the time-varying characteristics of DG output and load, a fault recovery framework for distribution networks based on a graph attention network (GAT) and soft actor–critic (SAC) algorithm is constructed, and the fault recovery method and its algorithm principle are introduced. Then, a graph-based deep reinforcement learning model for distribution network fault recovery is established. By embedding GAT into the pre-neural network of the SAC algorithm, the agent’s perception ability of the distribution network operation status and topology is improved, and an invalid action masking mechanism is innovatively introduced to avoid illegal actions. Through the interaction between the agent and the environment, the optimal switch action control strategy is found to realize the optimal learning of recovery under high DG penetration. Finally, the proposed method is verified on IEEE 33-bus and 148-bus examples and, compared with multiple baseline methods, the proposed method can achieve the fastest fault recovery at the millisecond level, and has a more efficient and superior recovery effect; the load supply rate under topology change increased by 4% to 5% compared with the benchmark model.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Dan et al. (2025) studied this question.

synapsesocial.com/papers/68af494dad7bf08b1ead4ba9https://doi.org/10.3390/en18164420
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Research on the harmonic currents rates for the exchanged energy of unified distributed power flow controller2022 · 16 citations
  2. 2Electric vehicle charging load forecasting considering weather impact2025 · 59 citations
  3. 3Analysis of Fault Characteristics of Distribution Network with PST Loop Closing Device under Small Current Grounding System2022 · 10 citations
  4. 4An expert system operational aid for restoration and loss reduction of distribution systems1988 · 484 citations
  5. 5Comprehensive review on the strategies for controlling the interconnection of AC and DC microgrids2021 · 128 citations