PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
August 22, 2025Journal of NeuroInterventional Surgery0 citations

Coil only middle meningeal artery embolization versus particles or liquid embolic agents for chronic subdural hematoma

View Full Paper
AFAdeline FeckerMMMatthew K. McIntyreHCHuanwen Chen

Key Points

  • Coil only embolization is associated with lower rates of altered mental status, diabetes, and thrombocytopenia, indicating fewer complications.
  • Among 168 patients evaluated, coil only and liquid/particle embolization had similar rates of surgical rescue and hematoma resorption, ensuring effective outcomes.
  • Retrospective analysis of patients from 2023 to 2025 highlights the safety of coil only embolization as a viable approach for chronic subdural hematoma management.
  • Results suggest that coil only embolization is a favorable option, indicating the need for further studies on embolization strategies involving vascular anastomoses.

Abstract

Background Middle meningeal artery embolization (MMAE) for chronic subdural hematoma (cSDH) with particles or liquid embolic agents has been shown to be effective, but can carry a theoretical risk of off-target embolization via dangerous collaterals and anastomoses. Primary coiling has been suggested as a safer alternative, particularly for patients with dangerous anastomoses. This study aims to evaluate the safety and efficacy of coil only for cSDH patients compared with liquid or particle embolic agents. Methods We performed a retrospective review of cSDH patients who underwent MMAE between 2023 and 2025. Patients were stratified by coil only versus liquid/particle embolization strategy. The primary outcome was rate of surgical rescue; secondary outcomes included the amount and rate of hematoma resorption. Subgroup analysis was performed among those with identified dangerous anastomoses. Results A total of 168 patients were included; 88 (52.4%) underwent coil only embolization. Coil only patients had significantly lower rates of altered mental status (P=0.010), diabetes (P=0.015), and thrombocytopenia (P0.05). Conclusions The results of the study indicate that coil only MMAE may be a safe and equally effective alternative to particle or liquid embolics for patients with cSDH.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Fecker et al. (2025) studied this question.

synapsesocial.com/papers/68af540fad7bf08b1eadb24bhttps://doi.org/10.1136/jnis-2025-023848
Ask AI
Helpful
Bookmark
Share
View Full Paper