PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
August 21, 2025Biosensors4 citationsOpen Access

A Novel Sensitive Recombinase-Aided Amplification Integrated Test Strip for Pseudomonas fluorescens in Milk via Dual Gene Probes

View Full Paper
GZGuangying ZhangLZLili ZhangJYJingqin Ye

Key Points

  • The detection system identifies Pseudomonas fluorescens with a limit of detection of 37 CFU/mL for gyrB within 90 minutes.
  • Compared to conventional PCR, the RAA-TS-DTL system increases sensitivity by four times, ensuring better identification.
  • The method uses dual gene probes to target virulence and housekeeping genes of Pseudomonas fluorescens.
  • This rapid detection tool shows 100% consistency with traditional culture methods in testing milk samples.

Abstract

Pseudomonas fluorescens is the main spoilage bacterium in milk, and its proliferation is one of the factors leading to the deterioration of the quality of raw milk. In this study, a rapid detection system for P. fluorescens was developed based on recombinase-aided amplification combined with a test strip (RAA-TS), which contained a double test line (DTL) targeting the virulence gene aprX of P. fluorescens and the housekeeping gene gyrB of Pseudomonas. Visual observation could detect gyrB (50 CFU/mL) and aprX (250 CFU/mL) within 90 min, including sample pretreatment and RAA reaction and detection steps. No cross-reactions were observed with Pseudomonas or other bacteria (n = 19). The quantitative detection limits (LOD) of gyrB and aprX for P. fluorescens in milk were 37 CFU/mL and 233 CFU/mL, respectively. Compared with polymerase chain reaction-agarose gel electrophoresis (PCR-AGE), the sensitivity of the developed RAA-TS-DTL system was increased by approximately four times. Furthermore, it could detect live P. fluorescens in milk when combined with optimized sample pretreatment by propidium monoazide (PMAxx). Its consistency with the traditional culture method in the detection of P. fluorescens spiked in milk samples (n = 25) was 100%. The developed RAA-TS-DTL had the advantages of high accuracy and short time consumption. Thus, it provides a new way or tool for the rapid screening or detection of P. fluorescens in milk.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Zhang et al. (2025) studied this question.

synapsesocial.com/papers/68af56f4ad7bf08b1eadd000https://doi.org/10.3390/bios15080553
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1A multiplex RPA-CRISPR/Cas12a-based POCT technique and its application in human papillomavirus (HPV) typing assay2024 · 61 citations
  2. 2A Rapid and Sensitive Detection Method for Pseudomonas aeruginosa Using Visualized Recombinase Polymerase Amplification and Lateral Flow Strip Technology2021 · 39 citations
  3. 3Cloning and characterization of Pfl_1841, a 2-methylenebornane synthase in Pseudomonas fluorescens PfO-12011 · 31 citations
  4. 4A Novel Tricolour Immunochromatographic Assay for Simultaneous Detection of Tricaine and Malachite Green2022 · 4 citations
  5. 5Matrix Effect on Butyltin Analysis of Sediments and Fish Tissues by GC-PFPD2013 · 7 citations