September 10, 2025Energies0 citationsOpen Access

Simulation and Finite Element Analysis of the Electrical Contact Characteristics of Closing Resistors Under Dynamic Closing Impacts

View Full Paper
YBYanyan BaoKLKang LiuXWXiao Wu

Key Points

  • Electrical contact resistance in closing resistors decreases temporarily during transient impacts, then recovers.
  • The simulation shows important effects like skin effect and current crowding that lead to localized heating.
  • Finite element analysis incorporates mechanical signals to simulate the real-time behavior under operational stresses.
  • Understanding these dynamics assists in the design optimization and assessment of ultra-high-voltage circuit breakers.

Abstract

Closing resistors in ultra-high-voltage (UHV) gas-insulated circuit breakers (GCBs) are critical components designed to suppress inrush currents and transient overvoltages during switching operations. However, in practical service, these resistors are subjected to repeated mechanical impacts and transient electrical stresses, leading to degradation of their electrical contact interfaces, fluctuating resistance values, and potential failure of the entire breaker assembly. Existing studies mostly simplify the closing resistor as a constant resistance element, neglecting the coupled electro-thermal–mechanical effects that occur during transient events. In this work, a comprehensive modeling framework is developed to investigate the dynamic electrical contact characteristics of a 750 kV GCB closing resistor under transient closing impacts. First, an electromagnetic transient model is built to calculate the combined inrush and power-frequency currents flowing through the resistor during its pre-insertion period. A full-scale mechanical test platform is then used to capture acceleration signals representing the mechanical shock imparted to the resistor stack. These measured signals are fed into a finite element model incorporating the Cooper–Mikic–Yovanovich (CMY) electrical contact correlation to simulate stress evolution, current density distribution, and temperature rise at the resistor interface. The simulation reveals pronounced skin effect and current crowding at resistor edges, leading to localized heating, while transient mechanical impacts cause contact pressure to fluctuate dynamically—resulting in a temporary decrease and subsequent recovery of contact resistance. These findings provide insight into the real-time behavior of closing resistors under operational conditions and offer a theoretical basis for design optimization and lifetime assessment of UHV GCBs.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Bao et al. (2025) studied this question.

synapsesocial.com/papers/68c189d99b7b07f3a06136e1https://doi.org/10.3390/en18174714
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Analysis of mechanical damage characteristics of closing resistor of 800kV tank circuit breaker with multi-physical field2024
  2. 2SF6 Experimental Study on the Variation Characteristics of Closing Prebreakdown Duration during Contact Deterioration of Circuit Breakers2024 · 2 citations
  3. 3Methodology for Circuit Breaker Contact Diagnosis through Dynamic Resistance Measurements and Fuzzy-Logic-Based Analysis2024 · 10 citations
  4. 4800 kV Fast Circuit Breaker: Mechanical Coupling Modelling, Buffer Design and Development2026
  5. 5The Impact of Various Contact Structures on the Microscopic Surface Condition of Vacuum Interrupters During Capacitive Switching2026