September 10, 2025Orthopaedic Proceedings0 citations

Are Modern Bearings Changing the Reasons for Revision in Total Hip Arthroplasty?

View Full Paper
EGEduardo García‐Rey

Key Points

  • Modern bearings in total hip arthroplasty reduce wear and osteolysis, improving longevity for patients.
  • Ceramic-on-ceramic and HXLPE significantly decreased wear rates, as confirmed by randomized controlled trials.
  • Surgeons at our institution prioritize non-modular components and smaller femoral heads to minimize complications.
  • New concerns have emerged regarding periprosthetic infections and dislocations as key revision reasons.

Abstract

During the last decades modern technology dramatically changed in total hip replacement (THR). After the promising results for low-friction arthroplasty developed by Sir John Charnley, wear and loosening were found at a long-term particularly in young patients. Uncemented fixation did not solve the problem of wear and osteolysis around THR, so researchers focused their research on bearing surfaces. Firstly, ceramic-on-ceramic couple was introduced due to their excellent characteristics in terms of tribology, wettability and biocompatibility. Last generation ceramics, both pure alumina and alumina matrix composite, improved strength and versatility. Nowadays, most surgeons use ceramic heads worldwide as first option in THR. More than 1,000 ceramic-on-ceramic THR have been implanted at our institution during the last 25 years showing encouraging results. Secondly, laboratory assays demonstrated that highly cross-linked polyethylene (HXLPE) liners decreased wear comparing to conventional polyethylene. After randomised controlled trials confirmed extremely early low-wear rates, HXLPE replaced old polyethylene worldwide due to their excellent clinical results at a medium- and long-term. We confirmed this excellent performance in a comparative study at a minimum follow-up of 20 years. Although modern bearing surfaces seem to solve the problem of wear and osteolysis at a long-term, there are other concerns in THR. Large femoral heads may result in problems of corrosion of the femoral neck, HXLPE and ceramic ruptures can occur, and modular components may result in adverse reactions. At our institution, surgeons did not use a modular stem or femoral heads larger than 36 mm. Clinical studies are essential to confirm the evolution of modern THR. Lastly, periprosthetic infection, dislocation and periprosthetic fractures are gaining importance as reasons for revision in THR.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Eduardo García‐Rey (2025) studied this question.

synapsesocial.com/papers/68c198b59b7b07f3a061a18fhttps://doi.org/10.1302/1358-992x.2025.6.085
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1BEARING SURFACE MATERIALS AND THE RISK OF REVISION FOLLOWING PRIMARY TOTAL HIP ARTHROPLASTY: A COHORT ANALYSIS OF 1,026,481 HIP ARTHROPLASTIES FROM THE NATIONAL JOINT REGISTRY2024
  2. 2Tribological Failure in Modern Total Hip Arthroplasty: A Narrative Review of Third-Body Wear, Oxidative Degradation, and Cross-Linked Polyethylene Longevity2026 · 1 citations
  3. 3THE ASSOCIATION OF BEARING SURFACE MATERIALS WITH THE RISK OF REVISION FOLLOWING PRIMARY TOTAL HIP ARTHROPLASTY: A COHORT ANALYSIS OF 1,026,481 HIP ARTHROPLASTIES FROM THE NATIONAL JOINT REGISTRY2024
  4. 4Advancements in ceramic-on-ceramic bearing materials for total hip arthroplasty: Properties, challenges, and future directions2024
  5. 5The Effect of Bearing Surface On the Survival of Cementless and Hybrid Total Hip Arthroplasty: An Analysis of Linked National Joint Registry and Hospital Episode Statistics Data2026