Investigating the Role of Fractals in Enhancing MRI Image Compression Techniques and Signal Processing Efficiency

View Full Paper
VSVikas SaxenaPMP. M. Mhatre

Key Points

  • The proposed fractal-based technique achieves 2 to 3 times faster compression of MRI images, enhancing efficiency.
  • Applying self-similarity in fractals improves the compression process, leading to a 10-unit increase in peak signal noise ratio.
  • The approach resolves conflicts between high compression rates and image quality, ensuring better diagnostic outcomes.
  • Transforming 3D MRI images into 2D series facilitates the use of fractal compression methods effectively.

Abstract

Magnetic Resonance Imaging (MRI) provides significant medical benefits by aiding physicians in clinical staging and predicting surgical extent. A substantial quantity of MRI images necessitates considerable storage capacity and transmission rates within the system for offline preservation and diagnosis from afar. The enlargement of superiorquality MRI pictures is very research-focused. Current MRI image compression algorithms that achieve substantial compression ratios result in loss of data regarding tumors, which can lead to misinterpretation; conversely, systems with low compression ratios fail to produce the desired outcomes. This research proposes a rapid fractal-based reduction technique for MRI pictures. Initially, three-dimensional (3D) MRI pictures are transformed into a twodimensional (2D) image series, enabling the sequence to utilize fractal compression. Range and area blocks are categorized based on the intrinsic spatiotemporal resemblance of three-dimensional objects. Applying self-similarity decreases the number of blocks in the comparing pool, enhancing the comparing speed of the suggested approach. A residual correction approach is implemented to attain high-quality decompression of MRI images using compressing. The experiments indicate that the reduction speed has increased by 2 to 3 times, and the Peak Signal Noise Ratio (PSNR) has increased by about 10. The suggested approach resolves the conflict between significant compression coefficients and the standard of MRI medical pictures.