September 10, 2025Energies0 citationsOpen Access

Experimental Testing and Seasonal Performance Assessment of a Stationary and Sun-Tracked Photovoltaic–Thermal System

View Full Paper
EKEwa Kozak-JagiełaPCPiotr CisekAPAdam Pawłowski

Key Points

  • The sun-tracked PVT system achieved 34% higher net electricity output compared to stationary systems, enhancing energy production.
  • Results showed that the stationary PVT system generated 26.1 kWh/m2 more electricity annually, indicating significant gains over conventional PV.
  • A novel cooling system improved thermal energy output by 85%, demonstrating efficient heat recovery capabilities of PVT systems.
  • Focusing on seasonal performance, sun-tracked systems showed notable improvements during autumn and winter, suggesting optimal deployment strategies.

Abstract

This study presents a comparative analysis of the annual performances of stationary and dual-axis sun-tracked photovoltaic–thermal (PVT) systems. The experimental research was conducted at a demonstration site in Oświęcim, Poland, where both systems were evaluated in terms of electricity and heat production. The test installation consisted of thirty stationary PVT modules and five dual-axis sun-tracking systems, each equipped with six PV modules. An innovative cooling system was developed for the PVT modules, consisting of a surface-mounted heat sink installed on the rear side of each panel. The system includes embedded tubes through which a cooling fluid circulates, enabling efficient heat recovery. The results indicated that the stationary PVT system outperformed a conventional fixed PV installation, whose expected output was estimated using PVGIS data. Specifically, the stationary PVT system generated 26.1 kWh/m2 more electricity annually, representing a 14.8% increase. The sun-tracked PVT modules yielded even higher gains, producing 42% more electricity than the stationary system, with particularly notable improvements during the autumn and winter seasons. After accounting for the electricity consumed by the tracking mechanisms, the sun-tracked PVT system still delivered a 34% higher net electricity output. Moreover, it enhanced the thermal energy output by 85%. The findings contribute to the ongoing development of high-performance PVT systems and provide valuable insights for their optimal deployment in various climatic conditions, supporting the broader integration of renewable energy technologies in building energy systems.