PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
September 12, 2025Journal of Ophthalmic and Vision Research0 citationsOpen Access

Characterization of the Pre-lens Tear Film in Hydrogel and Silicone Hydrogel Contact Lens Wear

View Full Paper
ANAndrea Novo‐DiezLVLaura Valencia‐NietoSPSara Pérez-Charro

Key Points

  • Tear film instability increased with both hydrogel and silicone hydrogel contact lenses, affecting pre-lens tear status.
  • Tear evaporation rates were significantly higher with both types of lenses compared to no lens wear.
  • The silicone hydrogel contact lens resulted in lower non-invasive tear break-up time than no lens wear.
  • Lipid layer thickness was reduced with hydrogel lenses compared to silicone hydrogel lenses and no lens wear.

Abstract

Purpose: Different contact lens (CL) materials have been associated with different behaviors of pre-lens tear film components in the short term. The purpose of this randomized crossover and double-masked study was to compare the effect of wearing hydrogel and silicone hydrogel CLs on pre-lens tear film status. Methods: Soft CL wearers were recruited and randomly fitted with a hydrogel (omafilcon A) and a silicone hydrogel (stenfilcon A) CL. Tear evaporation rate, non-invasive tear break-up time (NIBUT), tear film lipid layer thickness, and partial blink rate were measured without CLs and 30 minutes after the insertion of CLs. The outcomes were analyzed using repeated measures analysis of variance or the Friedman test. Results: Twenty-four CL wearers (6 men and 18 women) aged 23.3 ± 3.9 years were included. Tear evaporation rate was higher with the hydrogel CL (98.6 ± 59.4 g/m2/h; P = 0.043) and the silicone hydrogel CL (99.7 ± 60.6 g/m2/h; P = 0.037) compared to no CL wear (69.9 ± 41.3 g/m2/h). NIBUT was lower (P = 0.019) with the silicone hydrogel CL (12.7 ± 6.2 s) than with no CL wear (18.5 ± 9.8 s). Lipid layer thickness was lower with the hydrogel CL (64.9 ± 15.5) than with the silicone hydrogel CL (75.8 ± 14.0; P < 0.001) and no CL wear (75.9 ± 14.2; P = 0.001). No statistically significant differences were found in the partial blink rate. Conclusion: This study demonstrated that both hydrogel and silicone hydrogel CLs disrupt the tear film by increasing tear evaporation and causing tear film instability. However, CL materials affect the pre-lens tear film status differently. Further studies with longer wearing times are required.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Novo‐Diez et al. (2025) studied this question.

synapsesocial.com/papers/68d44c4631b076d99fa55a63https://doi.org/10.18502/jovr.v20.16812
Ask AI
Helpful
Bookmark
Share
View Full Paper