September 17, 2025Magnetic Resonance in Medicine3 citationsOpen Access

Combined angiography and perfusion using radial imaging and arterial spin labeling with structural contrast

View Full Paper
TOThomas W. OkellJWJoseph G. WoodsMCMark Chiew

Key Points

  • CAPRIA+S improves distal vessel visibility and reduces artifacts compared to traditional time-of-flight angiography.
  • This new imaging method provides comparable cerebral blood flow maps, proving its repeatability and efficiency.
  • Combined angiography and perfusion imaging can flexibly reconstruct information at varying resolutions and contrasts.
  • CAPRIA+S offers co-registered quantitative data on brain flow and structure, marking advantages over conventional imaging methods.

Abstract

To develop a non-contrast MRI method for the simultaneous acquisition of time-resolved 3D angiographic, perfusion, and multi-contrast T1-weighted structural brain images in a single 6 min acquisition. The proposed combined angiography and perfusion using radial imaging and arterial spin labeling with structural contrast (CAPRIA+S) pulse sequence uses pseudocontinuous arterial spin labeling to label inflowing blood, an inversion pulse to provide background suppression and T1-weighted contrast, and a continuous 3D golden ratio spoiled gradient echo readout. Label-control subtraction isolates the blood signal which can be flexibly reconstructed at high/low spatiotemporal resolution for angiography/perfusion imaging. The mean signal retains the static tissue, allowing T1-weighted structural images to be reconstructed at different effective TIs. CAPRIA+S was compared with conventional time-of-flight angiography, 3D-gradient and spin echo pseudocontinuous arterial spin labeling perfusion imaging, and MPRAGE structural imaging (10 min total) in healthy volunteers. CAPRIA+S gave improved distal vessel visibility and fewer artifacts than time-of-flight angiography, while also providing dynamic information, with blood transit time and dispersion maps. CAPRIA+S perfusion images were comparable to 3D-gradient and spin echo data but without through-slice blurring or artifacts in inferior brain regions. Comparable quantitative cerebral blood flow maps were produced, with CAPRIA+S being significantly more repeatable. Structural CAPRIA+S images were comparable to MPRAGE but also yielded a range of T1-weighted contrasts and allowed quantitative T1 maps to be estimated. CAPRIA+S is an efficient single acquisition to provide intrinsically co-registered quantitative information about brain blood flow and structure that has considerable advantages over conventional methods.