PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
September 17, 2025Bioengineering2 citationsOpen Access

Radiomics for Detecting Metaplastic Histology in Triple-Negative Breast Cancer: A Step Towards Personalized Therapy

View Full Paper
RCRana Günöz CömertGDGörkem DurakRYRavza Yılmaz

Key Points

  • Combined T1-weighted and STIR MRI analysis achieved an accuracy of 81% in distinguishing metaplastic breast cancer from non-metaplastic triple-negative breast cancer.
  • The study analyzed MRI data of 105 patients, with 27 diagnosed with metaplastic breast cancer and 78 with non-metaplastic triple-negative breast cancer.
  • Feature selection and classification were performed using machine learning techniques, including LASSO regression and seven classifiers assessed by ROC analysis.
  • The results indicate that multisequence MRI radiomics can effectively assist in treatment selection for patients with metaplastic breast cancer.

Abstract

This study aims to develop and validate a multisequence MRI-based radiomics approach for distinguishing metaplastic breast cancer (MBC) from non-metaplastic triple-negative breast cancer (TNBC) at the initial diagnosis, which could facilitate optimal treatment selection. In this retrospective study, we analyzed 105 patients (27 MBC, 78 non-metaplastic TNBC) who underwent standardized breast magnetic resonance imaging (MRI), which included T1-weighted contrast-enhanced (T1W-CE) and short-tau inversion recovery (STIR) sequences. Two radiologists performed ground truth lesion segmentation, verified by a senior radiologist. We extracted 214 radiomic features (using PyRadiomics) and used least absolute shrinkage and selection operator (LASSO) regression for feature selection. Seven machine learning classifiers were thoroughly evaluated using five-fold cross-validation, with performance assessed through ROC analysis and accuracy metrics. The combined T1W-CE and STIR analysis demonstrated superior diagnostic performance for distinguishing MBC from non-metaplastic TNBC (AUC = 0.845; accuracy = 81%) compared with either sequence alone (T1W only AUC = 0.805; accuracy = 80%; STIR only AUC:0.768; accuracy = 77%). Multisequence MRI radiomics can reliably distinguish between MBC and TNBC at the time of initial diagnosis. This could potentially facilitate the selection of more appropriate treatments and help avoid ineffective chemotherapy for MBC patients.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Cömert et al. (2025) studied this question.

synapsesocial.com/papers/68d4604031b076d99fa5f39ehttps://doi.org/10.3390/bioengineering12090973
Ask AI
Helpful
Bookmark
Share
View Full Paper