September 20, 2025Biomedicines2 citationsOpen Access

Thoracic MRI in Pediatric Oncology: Feasibility and Image Quality of Post-Contrast Free-Breathing Radial 3D T1 Weighted Imaging

View Full Paper
PTPatricia TischendorfMKMarc‐David KünnemannTKTobias Krähling

Key Points

  • The 3D T1w VANE mDIXON sequence yielded significantly higher image quality and reduced respiratory artifacts, promoting better diagnostic outcomes.
  • Signal-to-noise ratio measurements indicated a substantial increase, with values of 530 ± 120 for muscle and 570 ± 110 for liver compared to conventional methods.
  • Independent analysis demonstrated almost perfect interobserver agreement in image assessments, emphasizing reliability in diagnostic settings.
  • Using the free-breathing technique significantly reduced the need for general anesthesia, highlighting its practical advantages in pediatric imaging.

Abstract

Objectives: To compare the feasibility and image quality of a post-contrast free-breathing radial stack-of-stars 3D T1w turbo-field echo Dixon sequence (3D T1w VANE mDIXON) with a conventional cartesian breath-hold 3D T1w fast-field echo mDIXON sequence in pediatric oncology patients undergoing chest MRI. Methods: A total of 48 children (34 females; mean age 5.3 ± 3.7 years) underwent contrast-enhanced chest MRI, with 24 examined using the 3D T1w VANE mDIXON sequence and 24 with a conventional breath-hold 3D T1w mDIXON sequence. Image quality was independently assessed by three radiologists using a 5-point scale. Signal-to-noise ratio (SNR) was measured at two anatomical sites, a homogeneous paraspinal muscle region (SNRmuscle) and the liver apex (SNRliver), while avoiding vessels and signal inhomogeneities. The presence of respiratory artifacts, total imaging time, and the need for general anesthesia or sedation were recorded. Interobserver agreement was determined using Fleiss’s kappa (ϰ), and mean SNR values were compared between groups using an independent samples t-test. Results: The 3D T1w VANE mDIXON sequence yielded significantly higher SNRmuscle and SNRliver (530 ± 120; 570 ± 110 vs. 370 ± 110; 400 ± 90; p < 0.001), improved diagnostic image quality by approximately 25%, and reduced respiratory artifacts by about 23%. Interobserver agreement was almost perfect. Importantly, the need for general anesthesia was significantly reduced using the 3D T1w VANE mDIXON (p < 0.001). Conclusions: Free-breathing 3D T1w VANE mDIXON chest MRI is a feasible and effective imaging approach for pediatric oncology patients, offering superior image quality and reducing the need for general anesthesia compared to conventional methods.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Tischendorf et al. (2025) studied this question.

synapsesocial.com/papers/68d469c131b076d99fa66331https://doi.org/10.3390/biomedicines13092302
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Innovative 4D FreeBreathing technique in pediatric abdominal MRI improves feasibility and image quality2025 · 5 citations
  2. 2MRI and zero or ultra-short echo-time sequences in secondary interstitial lung diseases: current applicability and future perspectives2025 · 3 citations
  3. 3Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient Echo Sequence2011 · 296 citations
  4. 4Chest MRI Using Multivane-XD, a Novel T2-Weighted Free Breathing MR Sequence2019 · 7 citations
  5. 5Prospective Evaluation of Free-Breathing Fast T2-Weighted MultiVane XD Sequence at 3-T MRI for Large Airway Assessment in Pediatric Patients2021 · 14 citations