PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
September 20, 2025Journal of Applied Pharmaceutical Science0 citationsOpen Access

Supercritical fluid extraction, LC-MS profiling, and QbD-guided green HPLC method for standardization of Careya arborea Roxb. nanoemulsion

View Full Paper
ASAbhijit S. SalokheAPArchana S. PatilYGYadishma Gaude

Key Points

  • The extraction of (−)-epigallocatechin-3-gallate and azelaic acid was achieved using supercritical fluid extraction.
  • A robust HPLC method was developed for quantifying the bioactive compounds, ensuring high accuracy and precision.
  • The study utilized quality by design principles to optimize chromatographic parameters effectively.
  • Validation of the method confirmed its robustness and environmental sustainability using green chemistry metrics.

Abstract

Careya arborea Roxb. was investigated for its phytotherapeutic potential, focusing on two key bioactive constituents, (−)-epigallocatechin-3-gallate (EGCG) and azelaic acid (AzA). These compounds were efficiently extracted using supercritical fluid extraction (SFE), a green and selective technique. The chemical composition of the extract was confirmed through liquid chromatography–mass spectrometry (LC-MS), verifying the presence of both EGCG and AzA. To improve bioavailability and dermal absorption, the extract was formulated into a nanosuspension using suitable stabilizers and homogenization techniques. A robust and reproducible reverse-phase high-performance liquid chromatography method was developed for the quantitative estimation of EGCG and AzA in both the crude extract and nanosuspension. Method development was guided by a quality by design approach using central composite design, optimizing key chromatographic parameters with minimal experimentation. EGCG was separated using a Chemsil ODS C18 column with methanol and 0.1% orthophosphoric acid (60:40 v/v) at 276 nm, while AzA was analyzed using a Phenomenex Luna C18 column with acetonitrile and 0.1% formic acid (80:20 v/v) at 227 nm. The method was validated as per ICH Q2(R1) guidelines, showing high accuracy, precision, and robustness. Green chemistry metrics such as Analytical Eco-Scale and Analytical GREEnness confirmed the method’s environmental sustainability.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Salokhe et al. (2025) studied this question.

synapsesocial.com/papers/68d469c831b076d99fa6696bhttps://doi.org/10.7324/japs.2025.266427
Ask AI
Helpful
Bookmark
Share
View Full Paper