September 23, 2025Journal of Human Kinetics1 citationsOpen Access

Isokinetic vs. Hand-Held Dynamometry for Assessing Knee Flexor and Extensor Strength in Athletes: Evaluating a Low-Cost Alternative across the Range of Motion

View Full Paper
CKChristina KostiΑΤΑθανάσιος ΤσούκοςIPIakovos Pelekis

Key Points

  • Hand-held dynamometry produces reliable measurements of knee flexion and extension strength at various angles, showing good comparability to isokinetic results.
  • Peak extension torque was similar between hand-held dynamometry and isokinetic measures at all knee angles, with no significant differences found.
  • Angle-specific H/Q ratios obtained from hand-held dynamometry were comparable to those from isokinetic testing, highlighting its effectiveness across the range of motion.
  • The study supports using hand-held dynamometry as a valid alternative for assessing knee strength in athletes, offering a cost-effective solution.

Abstract

We explored whether hand-held dynamometry (HHD) could serve as a low-cost, portable alternative for assessing knee flexion and extension strength across the full range of motion. Twelve healthy athletes (7 men, 5 women; aged 21.4–28.5 years) performed maximal concentric (60°/s) and isometric flexion-extension efforts on an isokinetic dynamometer in prone and seated positions. On two separate occasions, peak extension and flexion torque were measured at six knee angles, and values obtained using HHD and isokinetic dynamometry (ISD) were compared at corresponding angles. HHD data demonstrated high reliability at all angles for knee flexion and extension (ICC = 0.812–0.971, p 0.38). Knee flexion torque was similar in HHD and seated ISD isometric measurements at all angles (p ≥ 0.48). The conventional hamstring to quadriceps (H/Q) ratio was similar in HHD and ISD in the seated position for both concentric and isometric measurements (56 ± 11%, 55 ± 8% and 51 ± 10%, respectively, p > 0.792). Angle-specific H/Q ratios from HHD were similar to those obtained by all modes of testing at all knee angles (p > 0.70), except for the knee angle of 10o, which was the position where the knee was almost extended. The highest H/Q ratios were observed at the knee angles of 10o and 30o (p < 0.001). HHD is valid and reliable for assessing knee strength, yielding results comparable to ISD across the range of motion of the knee joint. The findings also emphasize the importance of considering angle-specific H/Q ratios.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Kosti et al. (2025) studied this question.

synapsesocial.com/papers/68d4759031b076d99fa6d770https://doi.org/10.5114/jhk/210346