PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
September 24, 2025Magnetic Resonance Materials in Physics Biology and Medicine0 citationsOpen Access

Free-running time-resolved first-pass myocardial perfusion using a multi-scale dynamics decomposition: CMR-MOTUS

View Full Paper
TOThomas OlaussonMTMaarten L. TerpstraNHNiek R. F. Huttinga

Key Points

  • CMR-MOTUS significantly improves image similarity and motion field accuracy in myocardial perfusion imaging.
  • The method effectively captures both cardiac and respiratory motion dynamics, resulting in sharper cine images.
  • Joint reconstruction using CMR-MOTUS eliminates the need for pre-acquisition motion references, enhancing data efficiency.
  • Further clinical validations are needed to fully assess the diagnostic benefits of the CMR-MOTUS approach.

Abstract

Abstract Objective First-pass myocardial perfusion involves several types of dynamics, including cardiac motion, respiratory motion, bulk motion and contrast agent inflow. To accurately quantify the initial inflow of the contrast agent, high spatiotemporal resolution MR imaging must be obtained. To achieve this, we present a novel approach, named CMR-MOTUS, for the reconstruction of time-resolved free-running first-pass myocardial perfusion by jointly estimating high-quality motion fields and contrast-varying images. Materials and methods We propose CMR-MOTUS, which extends the MR-MOTUS framework by integrating a contrast-varying reference image with a low-rank plus sparse decomposition to capture additional dynamics such as blood flow and contrast agent inflow. This joint reconstruction framework alternates between solving for time-dependent image contrast changes and motion fields, eliminating the need for a pre-acquisition motion-static reference image. The method was tested on simulations and in-vivo datasets. Results In simulations, CMR-MOTUS showed improved image similarity and motion field accuracy compared to state-of-the-art methods. In in-vivo tests, the methods effectively captured cardiac and respiratory motion dynamics, resulting in cine images with sharper features than state-of-the-art. Discussion CMR-MOTUS presents significant advantages by modelling motion and contrast dynamics in the reconstruction of first-pass myocardial perfusion. The framework enables a data-efficient free-running workflow since the entire acquisition is correlated with high-quality motion fields. This approach has the potential to enhance the diagnostic value of cardiac MRI but needs further clinical validations.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Olausson et al. (2025) studied this question.

synapsesocial.com/papers/68d6d8ba8b2b6861e4c3efd5https://doi.org/10.1007/s10334-025-01291-x
Ask AI
Helpful
Bookmark
Share
View Full Paper