October 2, 2025Buildings2 citationsOpen Access

A Comparative Experimental Study on Seismic Retrofitting Techniques for RC Frames: RC Jacketing, Steel Jacketing, and Base Isolation

View Full Paper
WWWei-Lun WangMXMingyuan XieZXZhiwen Xu

Key Points

  • Base isolation shows superior energy dissipation capacity compared to traditional methods, effectively protecting structures.
  • Results from cyclic testing of four RC frame structures indicate enhanced seismic performance through base isolation.
  • Structural integrity is maintained as damage is redirected to newly installed transition beams instead of original columns.
  • The study supports the adoption of base isolation systems as an effective retrofitting approach in seismic-prone areas.

Abstract

Earthquakes can cause significant damage to structures, resulting in considerable financial and social losses. Enhancing the seismic capacity of existing structures through retrofitting is essential. Traditional seismic retrofitting techniques, such as reinforced concrete (RC) jacketing and steel jacketing, primarily aim to increase structural resistance. But RC jacketing is intrusive and increases mass and stiffness, steel jacketing increases cost and demands careful detailing and both approaches are often inadequate for addressing the dynamic complexities of seismic loading. As an alternative, base isolation systems provide a promising solution by concentrating deformation and energy dissipation within isolation bearings, thereby protecting the superstructure from seismic forces. This study evaluates the effectiveness of base isolation compared with conventional retrofitting methods in enhancing the seismic performance of existing structures. The experimental program included cyclic testing of four RC frame structures: one control specimen and three others retrofitted with RC jacketing, steel jacketing, and lead rubber bearings (LRB). The results indicate that the base-isolated specimen demonstrates superior energy dissipation capacity due to the favorable deformation characteristics of the LRB. Moreover, structural damage is redirected from the original columns to the newly installed transition beams, effectively preserving the integrity of the primary structure. These findings highlight the advantages of base isolation in improving seismic performance and provide valuable experimental evidence supporting its application in the retrofitting of existing structures.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Wang et al. (2025) studied this question.

synapsesocial.com/papers/68de6f3a83cbc991d0a2274ahttps://doi.org/10.3390/buildings15193539
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Seismic behavior of base-isolated building structures with lead rubber bearings (LRBs)2024 · 4 citations
  2. 2Seismic vulnerability assessment of RC structures: research and practice at building level2022 · 5 citations
  3. 3Effect of Lead-Rubber Bearing Isolators in Reducing Seismic Damage for a High-Rise Building in Comparison with Normal Shear Wall System2021 · 9 citations
  4. 4Influence of Vertical Irregularity on the Seismic Behavior of Base Isolated RC Structures with Lead Rubber Bearings under Pulse-Like Earthquakes2023 · 3 citations
  5. 5Influence of ground motion duration on seismic performance of RC frame isolated by high damping rubber bearings2022 · 33 citations