PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 7, 2025Journal of Applied Physics2 citationsOpen Access

Muon portable imager for counter-terrorism—MuPIC

View Full Paper
ADAlexander E. DunnAEA. ErlandsonDGDominique Godin

Key Points

  • The MuPIC system achieved a muon detection efficiency of 85%, enhancing its utility in imaging applications.
  • With an average position resolution of 2.52 mm, the detector provides accurate positioning for varied applications.
  • The design features double-sided readout of scintillator bars to improve light collection efficiency and performance consistency.
  • Field deployment is simplified due to the compact design of the MuPIC detector, highlighting its usability in real-world scenarios.

Abstract

We present recently developed portable muon tracking detectors based on robust and modern technology for imaging applications. Muon Portable Imager for Counter-terrorism (MuPIC) exploits triangular plastic scintillator bars with wavelength-shifting fiber optics along with silicon photomultipliers to improve detector performance over conventional photomultiplier technology. The muon detection efficiency was measured to be 85%, and the average position resolution is 2.52 mm for a given detector configuration. Improvements to light collection efficiency through double-sided readout of the scintillator bars decouple the detector performance from position dependence, in contrast with previous muon tomography detectors developed in Canada. The compact design of the MuPIC detector hardware directly enables field deployment with minimal complexity. We demonstrate the flexibility of the MuPIC detector through both scattering and attenuation tomography experiments.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Dunn et al. (2025) studied this question.

synapsesocial.com/papers/68e585d0b1e78cc4e5f4666ahttps://doi.org/10.1063/5.0287942
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Study on portable MUON tracker system based on position resolution Sealed MRPC2025
  2. 2Development of portable cosmic-ray muon detector array for muography2025 · 1 citations
  3. 3A borehole muon detector with SiPM-on-tile technology2025
  4. 4A Compact Two-Dimensional Radiation Detector for Educational Applications2025
  5. 5Fast timing detectors for the muon system of a muon collider experiment: requirements from simulation and prototype performance2024 · 4 citations