August 14, 2024Deleted Journal1 citationsOpen Access

An Image-Domain Deep-Learning Denoising Technique for Accelerated Parallel Brain MRI: Prospective Clinical Evaluation

View Full Paper
LOLaura OnacLDLorand DobaiAMAndrei Mouraviev

Key Points

Key points are not available for this paper at this time.

Abstract

Abstract Background Parallel imaging can accelerate MRI acquisitions, but excessive accelerations can introduce amplified noise and aliasing artifacts. Purpose To evaluate a vendor-agnostic AI-based approach to remove image degradation artifacts in highly accelerated MRI scans, improving image quality and reducing scan time. Materials and methods Training was performed by retrospectively degrading standard accelerated images. Evaluation was performed with both retrospective and prospectively-collected highly accelerated images. Retrospective data were taken from ∼2000 MRI studies obtained between August 2016 and October 2022, and prospective data were collected in 200 subjects between June and November 2022, using scanners from multiple vendors and locations. Scan time data were collected from prospective studies and used to compute time savings per sequence and per protocol for each vendor. Images were evaluated qualitatively by 5 board-certified radiologists and quantitatively by assessing noise, contrast, and spatial resolution. Paired Wilcoxon signed-rank tests were used to compare model outputs to model inputs and low-acceleration images. Results Images from 101 adults from 5 sites and 6 scanner models from different vendors were enrolled. 89% of imaged subjects had noteworthy imaging features or pathology. Model outputs were rated superior to model inputs (P .001) and most were either non-inferior (Pinf .05) or superior (Psup .05) to baseline images in qualitative metrics of image quality and feature visibility. Quantitative evaluation of signal-to-noise ratio and contrast-to-noise ratio improved for model outputs compared to inputs (P .001) or baseline images (P .005). Apparent resolution measured using the full width at half maximum or minimum was either enhanced (Psup .05) or preserved (non-superior Psup .05 and non-inferior Pinf .05). The scan time was reduced by an average of 29% (19%-41% per sequence). Conclusion This vendor-agnostic AI-based method achieved robust scan time savings without loss of image quality, potentially allowing for reduced cost and improved patient experience.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Onac et al. (2024) studied this question.

synapsesocial.com/papers/68e5c61db6db64358755c971https://doi.org/10.1093/radadv/umae022
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Accelerated MRI using intelligent protocolling and subject-specific denoising2024
  2. 2Deep Learning MRI Halves Scan Time and Preserves Image Quality Across Routine Neuroradiologic Examinations2025 · 4 citations
  3. 3Real-world unified denoising for multi-organ fast MRI: a large-scale prospective validation2026 · 1 citations
  4. 4Deep Learning-Based Acceleration in MRI: Current Landscape and Clinical Applications in Neuroradiology2025 · 16 citations
  5. 5Achieving Ultra-High Acceleration Rates in 7T MRI Using Combined Controlled Aliasing in Parallel Imaging and Compressed Sensing with Deep-Learning–Based Image Reconstruction2026 · 1 citations