PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
July 25, 20242 citationsOpen Access

Robustness of time domain near infrared spectroscopy to variations in skin pigmentation

View Full Paper
MLMichele LacerenzaCACaterina AmendolaIBIlaria Bargigia

Key Points

Key points are not available for this paper at this time.

Abstract

Abstract Recently, skin pigmentation has been shown to affect the performance of pulse oximeters and other light-based techniques like photoacoustic imaging, tissue oximetry, and continuous wave near infrared spectroscopy. Evaluating the robustness to changes in skin pigmentation is therefore essential for the proper use of optical technologies in the clinical scenario. We conducted systematic time domain near infrared spectroscopy measurements on calibrated tissue phantoms and in vivo on volunteers during static and dynamic (i.e., arterial occlusion) measurements. To simulate varying melanosome volume fractions in the skin, we inserted, between the target sample and the measurement probe, thin tissue phantoms made of silicone and nigrosine (skin phantoms). Additionally, we conducted an extensive measurement campaign on a large cohort of pediatric subjects, covering the full spectrum of skin pigmentation. Our findings consistently demonstrate that skin pigmentation has a negligible effect on time domain near infrared spectroscopy results, underscoring the reliability and potential of this emerging technology in diverse clinical settings.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Lacerenza et al. (2024) studied this question.

synapsesocial.com/papers/68e5f0b3b6db643587585be5https://doi.org/10.1101/2024.07.25.605070
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Melanometry for objective evaluation of skin pigmentation in pulse oximetry studies2024 · 43 citations
  2. 2Determination of visible near-IR absorption coefficients of mammalian fat using time- and spatially resolved diffuse reflectance and transmission spectroscopy2005 · 278 citations
  3. 3Pulse oximetry in primary care: factors affecting accuracy and interpretation2022 · 13 citations
  4. 4Effect of Skin Pigmentation on Pulse Oximetry Accuracy in the Emergency Department1998 · 107 citations
  5. 5Skin pigmentation interferes with the clinical measurement of regional cerebral oxygen saturation2014 · 52 citations