July 16, 2024Respiratory Care8 citations

The Impact of Increased PEEP on Hemodynamics, Respiratory Mechanics, and Oxygenation in Pediatric ARDS

View Full Paper
FJFernanda Maziero JunqueiraUniversidade Estadual de Campinas (UNICAMP)IFIsabel S. FerrazUniversidade Estadual de Campinas (UNICAMP)FCFábio Joly CamposUniversidade Estadual Paulista (Unesp)

Key Points

Key points are not available for this paper at this time.

Abstract

BACKGROUND: PEEP is a cornerstone treatment for children with pediatric ARDS. Unfortunately, its titration is often performed solely by evaluating oxygen saturation, which can lead to inadequate PEEP level settings and consequent adverse effects. This study aimed to assess the impact of increasing PEEP on hemodynamics, respiratory system mechanics, and oxygenation in children with ARDS. METHODS: Children receiving mechanical ventilation and on pressure-controlled volume-guaranteed mode were prospectively assessed for inclusion. PEEP was sequentially changed to 5, 12, 10, 8 cm H2O, and again to 5 cm H2O. After 10 min at each PEEP level, hemodynamic, ventilatory, and oxygenation variables were collected. RESULTS: A total of 31 subjects were included, with median age and weight of 6 months and 6.3 kg, respectively. The main reasons for pediatric ICU admission were respiratory failure caused by acute viral bronchiolitis (45%) and community-acquired pneumonia (32%). Most subjects had mild or moderate ARDS (45% and 42%, respectively), with a median (interquartile range) oxygenation index of 8.4 (5.8–12.7). Oxygen saturation improved significantly when PEEP was increased. However, although no significant changes in blood pressure were observed, the median cardiac index at PEEP of 12 cm H2O was significantly lower than that observed at any other PEEP level (P = .001). Fourteen participants (45%) experienced a reduction in cardiac index of > 10% when PEEP was increased to 12 cm H2O. Also, the estimated oxygen delivery was significantly lower, at 12 cm H2O PEEP. Finally, respiratory system compliance significantly reduced when PEEP was increased. At a PEEP of 12 cm H2O, static compliance had a median reduction of 25% in relation to the initial assessment (PEEP of 5 cm H2O). CONCLUSIONS: Although it may improve arterial oxygen saturation, inappropriately high PEEP levels may reduce cardiac output, oxygen delivery, and respiratory system compliance in pediatric subjects with ARDS with low potential for lung recruitability.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Junqueira et al. (2024) studied this question.

synapsesocial.com/papers/68e60139b6db643587595019https://doi.org/10.4187/respcare.12005
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Increasing tidal volumes and pulmonary overdistention adversely affect pulmonary vascular mechanics and cardiac output in a pediatric swine model1998 · 113 citations
  2. 2Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature2003 · 151 citations
  3. 3Evaluation of the multiple linear regression method to monitor respiratory mechanics in ventilated neonates and young children1992 · 46 citations
  4. 4Optimum End-Expiratory Airway Pressure in Patients with Acute Pulmonary Failure1975 · 1,306 citations
  5. 5G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences2007 · 65,958 citations