PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
July 11, 2024Sensors9 citationsOpen Access

Surface Plasmon Resonance Sensor Based on Fe2O3/Au for Alcohol Concentration Detection

View Full Paper
JWJunyi WangYXYanpei XuYSYutong Song

Key Points

Key points are not available for this paper at this time.

Abstract

Hematite (α-Fe2O3) is widely used in sensor sensitization due to its excellent optical properties. In this study, we present a sensitivity-enhanced surface plasmon resonance alcohol sensor based on Fe2O3/Au. We describe the fabrication process of the sensor and characterize its structure. We conduct performance testing on sensors coated multiple times and use solutions with the same gradient of refractive indices as the sensing medium. Within the refractive index range of 1.3335–1.3635, the sensor that was coated twice achieved the highest sensitivity, reaching 2933.2 nm/RIU. This represents a 30.26% enhancement in sensitivity compared to a sensor with a pure gold monolayer film structure. Additionally, we demonstrated the application of this sensor in alcohol concentration detection by testing the alcohol content of common beverages, showing excellent agreement with theoretical values and highlighting the sensor’s potential in food testing.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Wang et al. (2024) studied this question.

synapsesocial.com/papers/68e609c9b6db64358759d20bhttps://doi.org/10.3390/s24144477
Ask AI
Helpful
Bookmark
Share
View Full Paper