PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 19, 20242 citationsOpen Access

Evaluation of a reduced pressure chemical ion reactor utilizing adduct ionization for the detection of gaseous organic and inorganic species

View Full Paper
MRMatthieu RivaVPVeronika PospíšilováCFCarla Frege

Key Points

Key points are not available for this paper at this time.

Abstract

Abstract. Volatile organic compounds (VOCs) and volatile inorganic compounds (VICs) provide critical information across many scientific fields including atmospheric chemistry, soil, and biological processes. Chemical ionization (CI) mass spectrometry has become a powerful tool for tracking these chemically complex and temporally variable compounds in a variety of laboratory and field environments. It is particularly powerful with time-of-flight mass spectrometers, which can measure hundreds of compounds in a fraction of a second and have enabled entirely new branches of VOC/VIC research in atmospheric and biological chemistry. To accurately describe each step of these chemical, physical, and biological processes, measurements across the entire range of gaseous products is crucial. Recently, chemically comprehensive gas-phase measurements have been performed using many CI mass spectrometers deployed in parallel, each utilizing a different ionization method to cover a broad range of compounds. Here we introduce the recently developed Vocus AIM (Adduct Ionization Mechanism) ion-molecule reactor (IMR), which samples trace vapors in air and ionizes them via chemical ionization at medium pressures. The Vocus AIM supports the use of many different reagent ions of positive and negative polarity and is largely independent of changes in the sample humidity. Within the present study, we present the performance and explore the capabilities of the Vocus AIM using various chemical ionization schemes, including Chloride (Cl–), Bromide (Br–), Iodide (I–), Nitrate (NO3–), Benzene cations (C6H6+), Acetone dimers ((C3H6O)2H+), and Ammonium (NH4+) reagent ions primarily in laboratory and flow tube experiments. We report the technical characteristics, operational principles, and compare its performance in terms of time response, humidity dependence, and sensitivity to that of previous chemical ionization approaches. This work demonstrates the benefits of the Vocus AIM reactor which provides a versatile platform to characterize VOCs and VICs in real time at trace concentrations.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Riva et al. (2024) studied this question.

synapsesocial.com/papers/68e6e752b6db64358766265ehttps://doi.org/10.5194/egusphere-2024-945
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1All-in-One: Validation and Versatile Applications of a Novel Chemical Ionization Mass Spectrometer for Simultaneous Measurements of Volatile Organic and Inorganic Compounds2025
  2. 2All-in-one: validation and versatile applications of a novel chemical ionization mass spectrometer for simultaneous measurements of volatile organic and inorganic compounds2026 · 1 citations
  3. 3Deployment and evaluation of an NH<sub>4</sub><sup>+</sup>/H<sub>3</sub>O<sup>+</sup> reagent-ion switching chemical ionization mass spectrometer for the detection of reduced and oxygenated gas-phase organic compounds2024 · 1 citations
  4. 4&amp;#173;&amp;#173;Non-targeted VOC Quantification through the Simultaneous Coupling of an in-situ Gas Chromatograph to Electron and Chemical Ionization Time-of-Flight Mass Spectrometers2024
  5. 5Voltage scanning to calibrate Multi-Reagent Chemical Ionization Mass Spectrometers (MR-CIMS): from signal to sensitivity2026