PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 1, 2024European Heart Journal Supplements0 citationsOpen Access

Severe Mitral Regurgitation Treated With Transcatheter Aortic Valve Implantation in Mitral Ring (Tmvir): A Case Report

View Full Paper
CVChristina L. VitaleCGC GianniniGCGiulia Costa

Key Points

Key points are not available for this paper at this time.

Abstract

Abstract Introduction The increasing prevalence of mitral regurgitation (MR), combined with a growing population of elderly patients at risk of being unsuitable for surgical options, has led to a greater interest in the use of less invasive treatments such as transcatheter heart valve (THV) implantation. This case involves the use of transcatheter aortic valve implantation in a patient with a previous mitral annuloplasty (TMViR). Case Presentation A 77–year–old woman had previously undergone mitral annuloplasty (Physio Ring II 32 mm, Medtronic), Neocord implantation and closure of the posterior commissure for severe MR due to anterior leaflet prolapse. She presented to our attention with worsening dyspnea (NYHA Class III) and a sudden weight gain. Transesophageal echocardiogram (TEE) revealed findings indicative of a previous mitral annuloplasty failure, with residual severe MR along with severe tricuspid regurgitation (TR). The case was discussed in the Heart Team and given the elevated surgical risk and the patient‘s anatomical unsuitability for edge–to–edge therapy, it was decided to perform a TMViR implantation. Under echocardiographic guidance and general anesthesia, right common right femoral vein access was obtained. After transseptal puncture, predilation of the interatrial septum was performed with balloon (Evercross 12 mm, Medtronic). Subsequent access to the left ventricle was achieved with a 6F PigTail catheter, and a stiff exchange guide (Safari S, Boston Scientific) was used to advance the 16Fr Delivery system. With the assistance of TEE, aortic valve implantation on the mitral ring was performed (Sapien 29 mm, Edwards Lifesciences) with rapid pacing via transvenous temporary PM placed in right ventricle (Spikeflow, Fiab). At the end of the procedure, two closure systems (Proglide, Abbott) were used for right femoral vein access. Post–implantation TEE showed a trivial paravalvular leak external to the annulus and a mean transvalvular gradient of 5 mmHg. The postoperative course proceeded without complications, facilitating the patient‘s discharge on the third postoperative day. Currently no further hospitalization in the last 6 months. Conclusion Despite surgical intervention remaining the gold standard in treating severe MR in patients who have undergone a previous annuloplasty, in patients at high surgical risk for a re–operation, who are not eligible for other percutaneous options, TMViR could be a safe and effective option for treatment.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Vitale et al. (2024) studied this question.

synapsesocial.com/papers/68e716f6b6db64358768f910https://doi.org/10.1093/eurheartjsupp/suae036.411
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Transcatheter Mitral Valve Implantation (TMVI) Using Edwards SAPIEN 3 Prostheses in Patients at Very High or Prohibitive Surgical Risk: A Single-Center Experience2020 · 14 citations
  2. 2Totally endoscopic mitral valve replacement for mitral regurgitation post-transcatheter aortic valve implantation: a case report2025
  3. 3Transcatheter Mitral Valve Replacement in Patients With Previous Aortic Valve Replacement2018 · 23 citations
  4. 4Transapical mitral valve implantation for treatment of symptomatic mitral valve disease: a real‐world multicentre experience2022 · 63 citations
  5. 5Transcatheter valve-in-ring implantation after failure of surgical mitral repair2013 · 121 citations