March 23, 2024Energy Reports6 citationsOpen Access

Non-unit protection method for MMC-HVDC grids based on selective drop rate of voltage traveling waves

View Full Paper
FMFarzad Dehghan MarvastiAMAhmad MirzaeiMSMehdi Savaghebi

Key Points

Key points are not available for this paper at this time.

Abstract

Fast, sensitive, and selective protection principles are one of the major challenges in the feasibility of modular multi-terminal (MMC) high voltage direct current (HVDC) grids. Rate of change of voltage (ROCOV) and transient-based solutions are the traditional and widely accepted protection principles. Despite the speed and practicality of these solutions, they generally suffer from sensitivity and selectivity issues, particularly when dealing with high-resistance faults and low-size current limiting inductors (CLIs). To improve upon these methods, this paper proposes a new primary protection method that utilizes a selective drop rate of fault-generated voltage traveling waves (TW) to detect internal DC line faults. This is achieved by a comprehensive analysis of the line-mode fault-generated voltage (LFGV) under various internal and external fault scenarios. As the key fault characteristics, the proposed method exploits the minimum points of initial LFGV and the corresponding time to form the basis of the proposed protection method. The effectiveness of this approach is evaluated using a four-terminal MMC-HVDC grid in PSCAD/EMTDC. Compared to ROCOV and transient-based solutions, the proposed method identifies internal faults up to 1250 Ω with fast response, while maintaining its practicality and independence to CLI size.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Marvasti et al. (2024) studied this question.

synapsesocial.com/papers/68e72a7db6db6435876a47f1https://doi.org/10.1016/j.egyr.2024.03.045
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Non-Unit Ultra-High-Speed DC Line Protection Method for HVDC Grids Using First Peak Time of Voltage2020 · 49 citations
  2. 2Study on the dynamic performance characteristics of HVDC control and protections for the HVDC line fault2009 · 106 citations
  3. 3Fault Detection and Interruption in an Earthed HVDC Grid Using ROCOV and Hybrid DC Breakers2014 · 474 citations
  4. 4Fault Analysis and Traveling-Wave Protection Scheme for Bipolar HVDC Lines2012 · 273 citations
  5. 5Negative sequence current accumulation difference based wind farm collection line protection for MMC-HVDC system2023 · 3 citations