PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 19, 2024Magnetic Resonance in Medicine6 citationsOpen Access

Technical advances in motion‐robust MR thermometry

View Full Paper
KKKi Soo KimKNKazim NarsinhEOEugene Ozhinsky

Key Points

Key points are not available for this paper at this time.

Abstract

Abstract Proton resonance frequency shift (PRFS) MR thermometry is the most common method used in clinical thermal treatments because of its fast acquisition and high sensitivity to temperature. However, motion is the biggest obstacle in PRFS MR thermometry for monitoring thermal treatment in moving organs. This challenge arises because of the introduction of phase errors into the PRFS calculation through multiple methods, such as image misregistration, susceptibility changes in the magnetic field, and intraframe motion during MRI acquisition. Various approaches for motion correction have been developed for real‐time, motion‐robust, and volumetric MR thermometry. However, current technologies have inherent trade‐offs among volume coverage, processing time, and temperature accuracy. These tradeoffs should be considered and chosen according to the thermal treatment application. In hyperthermia treatment, precise temperature measurements are of increased importance rather than the requirement for exceedingly high temporal resolution. In contrast, ablation procedures require robust temporal resolution to accurately capture a rapid temperature rise. This paper presents a comprehensive review of current cutting‐edge MRI techniques for motion‐robust MR thermometry, and recommends which techniques are better suited for each thermal treatment. We expect that this study will help discern the selection of motion‐robust MR thermometry strategies and inspire the development of motion‐robust volumetric MR thermometry for practical use in clinics.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Kim et al. (2024) studied this question.

synapsesocial.com/papers/68e734fcb6db6435876ae775https://doi.org/10.1002/mrm.30057
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Multi‐echo MR thermometry using iterative separation of baseline water and fat images2018 · 24 citations
  2. 2A k‐space‐based method to measure and correct for temporal B0 field variations in MR temperature imaging2022 · 14 citations
  3. 3Deep correction of breathing-related artifacts in real-time MR-thermometry2020 · 10 citations
  4. 4Spectrally selective pencil‐beam navigator for motion compensation of MR‐guided high‐intensity focused ultrasound therapy of abdominal organs2011 · 44 citations
  5. 5Breath-hold MR-HIFU hyperthermia: phantom and in vivo feasibility2019 · 37 citations