Influence of reference transducer location on hearing protector attenuation metrics for impulse noise

View Full Paper
WMWilliam J. MurphySTStephen M. TaskoGFGregory A. Flamme

Key Points

Key points are not available for this paper at this time.

Abstract

The ANSI/ASA S12.42-2010 standard can be used to estimate the attenuation for impulsive noises between 130 and 170 decibels peak sound pressure level (dB pSPL). The ANSI/ASA S12.42 method uses a complex transfer function between the signal received in the ear of an acoustic test fixture (ATF) and a reference transducer. The reference transducer is at the same radial distance from the impulse source and at less than 30 degrees from the ATF angle. The reference transducer is specified as a pencil-type pressure ( 40.6 cm long). The maximum angle and the minimum pencil probe dimensions could be incompatible near the source, or may introduce artifacts or hazards. In this study, several hearing protectors were evaluated with two rifles (A-Bolt .300 Winchester Magnum and Colt AR-15 5.56 caliber), two ATFs (GRAS 45CB), and five transducers (four ¼” microphones and one surface mount microphone). The ATFs were on opposite sides of the gun at distances for field levels between 180- and 140-dB pSPL. For each location and rifle, S12.42 metrics were calculated for all 20 combinations of ATF ear and reference transducer. Results indicated that S12.42 metrics were minimally affected by the locations of the reference transducers.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Murphy et al. (2024) studied this question.

synapsesocial.com/papers/68e76bd8b6db6435876e1e56https://doi.org/10.1121/10.0026819
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Comparison of two acoustic test fixtures for measuring impulse level dependent attenuation2024
  2. 2Measuring hearing protector attenuation of impulse noise on acoustic test fixtures using maximum A-weighted energy reduction2024
  3. 3Earmuff performance in the presence of high-level impulse from a recoilless weapon firing in a confined space2024 · 1 citations
  4. 4Evaluation of a multi-function in-ear device performance in the presence of impulse noise using acoustic test fixtures2024 · 1 citations
  5. 5Effect of shooting glasses on earmuff attenuation measured with an acoustic test fixture for gunfire impulses2024