PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 14, 2024Advanced Healthcare Materials60 citationsOpen Access

Recording Quality Is Systematically Related to Electrode Impedance

View Full Paper
CLChris LewisCBChristian BoehlerRLRickard Liljemalm

Key Points

Key points are not available for this paper at this time.

Abstract

Extracellular recordings with planar microelectrodes are the gold standard technique for recording the fast action potentials of neurons in the intact brain. The introduction of microfabrication techniques has revolutionized the in vivo recording of neuronal activity and introduced high-density, multi-electrode arrays that increase the spatial resolution of recordings and the number of neurons that can be simultaneously recorded. Despite these innovations, there is still debate about the ideal electrical transfer characteristics of extracellular electrodes. This uncertainty is partly due to the lack of systematic studies comparing electrodes with different characteristics, particularly for chronically implanted arrays over extended time periods. Here a high-density, flexible, and thin-film array is fabricated and tested, containing four distinct electrode types differing in surface material and surface topology and, thus, impedance. It is found that recording quality is strongly related to electrode impedance with signal amplitude and unit yield negatively correlated to impedance. Electrode impedances are stable for the duration of the experiment (up to 12 weeks) and recording quality does not deteriorate. The findings support the expectation from the theory that recording quality will increase as impedance decreases.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Lewis et al. (2024) studied this question.

synapsesocial.com/papers/68e792b5b6db643587703630https://doi.org/10.1002/adhm.202303401
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes2015 · 417 citations
  2. 2Toward the ultimate metal microelectrode1995 · 113 citations
  3. 3Tutorial: guidelines for standardized performance tests for electrodes intended for neural interfaces and bioelectronics2020 · 319 citations
  4. 4High-Density, Long-Lasting, and Multi-region Electrophysiological Recordings Using Polymer Electrode Arrays2018 · 365 citations
  5. 5Ultraflexible electrode arrays for months-long high-density electrophysiological mapping of thousands of neurons in rodents2022 · 179 citations