PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 17, 2025Global Spine Journal1 citationsOpen Access

Augmented Reality–Guided Pedicle Screw Placement With 2D–3D Registration: Proof-Of-Concept Using 151 Cadaveric Trajectories

View Full Paper
JCJosé A. García del CastilloGUGabriel UrreolaVKVenina Kalistratova

Key Points

  • 147 of 151 pedicle screws were accurately positioned in the 'safe zone', demonstrating a high accuracy rate of 97.4%.
  • The upper bound limit for angular errors was less than 3 degrees, and translational errors were less than 3 mm across all vertebral levels.
  • This study utilized a prospective single-center cadaveric approach with six human specimens for evaluation.
  • The 2D-3D registration with augmented reality shows promise for improving surgical navigation techniques.

Abstract

Study Design Prospective, single-center cadaveric study. Objectives To evaluate the accuracy of augmented reality (AR) head-mounted display navigation using a 2D-3D registration method for pedicle screw placement that integrates preoperative CT scans with intraoperative X-ray images, eliminating the need for intraoperative 3D imaging. Methods A prospective, single-center cadaveric study was conducted using six human cadaveric specimens. Five board-certified spine surgeons placed 151 pedicle screws across cervical (n = 36), thoracic (n = 54), lumbar (n = 41), and sacroiliac (n = 20) regions using an AR navigation system. The system utilized preoperative CT scans registered with intraoperative X-ray images. Accuracy was assessed stereotactically (angular and translational errors) and clinically (Gertzbein-Robbins and Heary classifications). Results Of 151 pedicle screws placed, 147 (97.4%) were accurately positioned in the “safe zone” (Gertzbein-Robbins grades A/B or Heary classifications I/II). The 99% upper bound limit for angular errors was <3 and translational errors was < 3 mm in both axial and sagittal planes across all vertebral levels. Conclusions The 2D-3D registration methodology with AR visualization demonstrates high accuracy for pedicle screw placement comparable to conventional navigation techniques. This approach effectively addresses key limitations of existing navigation paradigms while maintaining high accuracy standards without requiring intraoperative 3D imaging capabilities. AR-assisted navigation with 2D-3D registration represents a promising technological advancement that may enhance the precision and efficiency of spinal instrumentation procedures.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Castillo et al. (2025) studied this question.

synapsesocial.com/papers/68f19f1ade32064e504dd847https://doi.org/10.1177/21925682251387550
Ask AI
Helpful
Bookmark
Share
View Full Paper